Snapshot status

time:21 Dec 2017 19:45
maximum capacity:1680 (model units)
available capacity:1680 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The system loss analysis. The losses are relative to the system maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(k model units) (k model units) (k model units) (k model units) (%) (%)
upstream 1.54 0 0.0146 1.55 99.1 99.1
midstream 1.49 0.03 0.0306 1.55 96.1 98.0
system 1.48 0.03 0.0443 1.55 95.2 97.1

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:1680 (model units)
available capacity:1680 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The upstream loss analysis. The losses are relative to the upstream maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(k model units) (k model units) (k model units) (k model units) (%) (%)
field1 0.827 0 0.0226 0.85 97.3 97.3
field2 0.396 0 0.0116 0.408 97.1 97.1
field3 0.414 0 0.0112 0.425 97.4 97.4
upstream 1.64 0 0.0454 1.68 97.3 97.3

The upstream criticality ranking. The losses are relative to the upstream maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(k model units) (k model units) (k model units) (%)
other 1.11E-34 1.683 1.88E-34 1.68 0.0
other 8.4E-45 1.547 1.3E-44 1.68 0.0
other 5.16E-43 1.53 7.88E-43 1.68 0.0
other 1.49E-30 1.513 2.26E-30 1.68 0.0
other 1.32E-39 1.496 1.97E-39 1.68 0.0
other 5.24E-38 1.479 7.75E-38 1.68 0.0
other 1.78E-36 1.462 2.6E-36 1.68 0.0
other 5.12E-35 1.445 7.4E-35 1.68 0.0
other 1.25E-33 1.428 1.79E-33 1.68 0.0
other 2.6E-32 1.411 3.66E-32 1.68 0.0
other 4.5E-31 1.394 6.28E-31 1.68 0.0
other 6.47E-30 1.377 8.91E-30 1.68 0.0
other 7.58E-29 1.36 1.03E-28 1.68 0.0
other 9.78E-27 1.343 1.31E-26 1.68 0.0
other 5.05E-27 1.326 6.7E-27 1.68 0.0
other 2.64E-26 1.309 3.46E-26 1.68 0.0
other 9.17E-26 1.292 1.18E-25 1.68 0.0
other 1.75E-25 1.275 2.23E-25 1.68 0.0
other 1.03E-25 1.258 1.29E-25 1.68 0.0
other 2.53E-28 1.241 3.14E-28 1.68 0.0
other 4.39E-27 1.224 5.37E-27 1.68 0.0
other 6.3E-26 1.207 7.61E-26 1.68 0.0
other 7.38E-25 1.19 8.78E-25 1.68 0.0
other 3.96E-23 1.173 4.65E-23 1.68 0.0
other 4.92E-23 1.156 5.69E-23 1.68 0.0
other 2.57E-22 1.139 2.93E-22 1.68 0.0
other 8.93E-22 1.122 1.0E-21 1.68 0.0
other 1.71E-21 1.105 1.89E-21 1.68 0.0
other 1.0E-21 1.088 1.09E-21 1.68 0.0
other 1.2E-24 1.071 1.28E-24 1.68 0.0
other 2.02E-23 1.054 2.13E-23 1.68 0.0
other 2.86E-22 1.037 2.97E-22 1.68 0.0
other 3.33E-21 1.02 3.4E-21 1.68 0.0
other 1.08E-19 1.003 1.08E-19 1.68 0.0
other 2.23E-19 0.986 2.2E-19 1.68 0.0
other 1.19E-18 0.969 1.15E-18 1.68 0.0
other 4.37E-18 0.952 4.16E-18 1.68 0.0
other 1.01E-17 0.935 9.42E-18 1.68 0.0
other 1.57E-17 0.918 1.44E-17 1.68 0.0
other 3.62E-17 0.901 3.27E-17 1.68 0.0
other 8.47E-17 0.884 7.49E-17 1.68 0.0
other 1.3E-16 0.867 1.13E-16 1.68 0.0
other 1.06E-16 0.85 9.02E-17 1.68 0.0
other 2.01E-16 0.833 1.67E-16 1.68 0.0
other 5.84E-16 0.816 4.76E-16 1.68 0.0
other 3.19E-15 0.799 2.55E-15 1.68 0.0
other 1.25E-14 0.782 9.79E-15 1.68 0.0
other 3.44E-14 0.765 2.64E-14 1.68 0.0
other 7.95E-14 0.748 5.95E-14 1.68 0.0
other 2.21E-13 0.731 1.61E-13 1.68 0.0
other 5.15E-13 0.714 3.68E-13 1.68 0.0
other 7.89E-13 0.697 5.5E-13 1.68 0.0
other 6.07E-13 0.68 4.12E-13 1.68 0.0
other 2.51E-13 0.663 1.67E-13 1.68 0.0
other 9.22E-13 0.646 5.96E-13 1.68 0.0
other 5.17E-12 0.629 3.25E-12 1.68 0.0
other 2.14E-11 0.612 1.31E-11 1.68 0.0
other 6.66E-11 0.595 3.96E-11 1.68 0.0
other 1.84E-10 0.578 1.06E-10 1.68 0.0
other 5.37E-10 0.561 3.01E-10 1.68 0.0
other 1.26E-9 0.544 6.84E-10 1.68 0.0
other 1.93E-9 0.527 1.01E-9 1.68 0.0
other 1.48E-9 0.51 7.55E-10 1.68 0.0
other 2.62E-10 0.493 1.29E-10 1.68 0.0
other 9.97E-10 0.476 4.75E-10 1.68 0.0
other 5.13E-9 0.459 2.35E-9 1.68 0.0
other 2.15E-8 0.442 9.49E-9 1.68 0.0
other 7.19E-8 0.425 3.06E-8 1.68 0.0
other 2.18E-7 0.408 8.9E-8 1.68 0.0
other 6.55E-7 0.391 2.56E-7 1.68 0.0
other 1.53E-6 0.374 5.74E-7 1.68 0.0
other 2.36E-6 0.357 8.43E-7 1.68 0.0
other 1.85E-6 0.34 6.29E-7 1.68 0.0
other 3.18E-7 0.323 1.03E-7 1.68 0.0
other 9.23E-7 0.306 2.82E-7 1.68 0.0
other 3.22E-6 0.289 9.31E-7 1.68 0.0
other 1.17E-5 0.272 3.19E-6 1.68 0.0
other 4.02E-5 0.255 1.03E-5 1.68 0.0
other 1.31E-4 0.238 3.12E-5 1.68 0.0
other 4.02E-4 0.221 8.88E-5 1.68 0.0
other 9.49E-4 0.204 1.94E-4 1.68 0.0
other 0.00151 0.187 2.82E-4 1.68 0.0
other 0.00142 0.17 2.41E-4 1.68 0.0
other 0.00128 0.153 1.96E-4 1.68 0.0
other 0.00421 0.136 5.73E-4 1.68 0.0
other 0.0124 0.119 0.00148 1.68 0.1
other 0.0325 0.102 0.00332 1.68 0.2
other 0.0739 0.085 0.00628 1.68 0.4
⊥ ( V6001 ⊥ ( V6002 V6003)) 0.0137 0.068 9.31E-4 1.68 0.1
other 0.141 0.068 0.00956 1.68 0.6
other 0.214 0.051 0.0109 1.68 0.6
other 0.243 0.034 0.00825 1.68 0.5
well001 0.00184 0.017 3.13E-5 1.68 0.0
well002 0.00184 0.017 3.13E-5 1.68 0.0
well003 0.00184 0.017 3.13E-5 1.68 0.0
well004 0.00184 0.017 3.13E-5 1.68 0.0
well005 0.00184 0.017 3.13E-5 1.68 0.0
well006 0.00184 0.017 3.13E-5 1.68 0.0
well007 0.00184 0.017 3.13E-5 1.68 0.0
well008 0.00184 0.017 3.13E-5 1.68 0.0
well009 0.00184 0.017 3.13E-5 1.68 0.0
well010 0.00184 0.017 3.13E-5 1.68 0.0
well011 0.00184 0.017 3.13E-5 1.68 0.0
well012 0.00184 0.017 3.13E-5 1.68 0.0
well013 0.00184 0.017 3.13E-5 1.68 0.0
well014 0.00184 0.017 3.13E-5 1.68 0.0
well015 0.00184 0.017 3.13E-5 1.68 0.0
well016 0.00184 0.017 3.13E-5 1.68 0.0
well017 0.00184 0.017 3.13E-5 1.68 0.0
well018 0.00184 0.017 3.13E-5 1.68 0.0
well019 0.00184 0.017 3.13E-5 1.68 0.0
well020 0.00184 0.017 3.13E-5 1.68 0.0
well021 0.00184 0.017 3.13E-5 1.68 0.0
well022 0.00184 0.017 3.13E-5 1.68 0.0
well023 0.00184 0.017 3.13E-5 1.68 0.0
well024 0.00184 0.017 3.13E-5 1.68 0.0
well025 0.00184 0.017 3.13E-5 1.68 0.0
well026 0.00184 0.017 3.13E-5 1.68 0.0
well027 0.00184 0.017 3.13E-5 1.68 0.0
well028 0.00184 0.017 3.13E-5 1.68 0.0
well029 0.00184 0.017 3.13E-5 1.68 0.0
well030 0.00184 0.017 3.13E-5 1.68 0.0
well031 0.00184 0.017 3.13E-5 1.68 0.0
well032 0.00184 0.017 3.13E-5 1.68 0.0
well033 0.00184 0.017 3.13E-5 1.68 0.0
well034 0.00184 0.017 3.13E-5 1.68 0.0
well035 0.00184 0.017 3.13E-5 1.68 0.0
well036 0.00184 0.017 3.13E-5 1.68 0.0
well037 0.00184 0.017 3.13E-5 1.68 0.0
well038 0.00184 0.017 3.13E-5 1.68 0.0
well039 0.00184 0.017 3.13E-5 1.68 0.0
well040 0.00184 0.017 3.13E-5 1.68 0.0
well041 0.00184 0.017 3.13E-5 1.68 0.0
well042 0.00184 0.017 3.13E-5 1.68 0.0
well043 0.00184 0.017 3.13E-5 1.68 0.0
well044 0.00184 0.017 3.13E-5 1.68 0.0
well045 0.00184 0.017 3.13E-5 1.68 0.0
well046 0.00184 0.017 3.13E-5 1.68 0.0
well047 0.00184 0.017 3.13E-5 1.68 0.0
well048 0.00184 0.017 3.13E-5 1.68 0.0
well049 0.00184 0.017 3.13E-5 1.68 0.0
well050 0.00184 0.017 3.13E-5 1.68 0.0
well051 0.00184 0.017 3.13E-5 1.68 0.0
well052 0.00184 0.017 3.13E-5 1.68 0.0
well053 0.00184 0.017 3.13E-5 1.68 0.0
well054 0.00184 0.017 3.13E-5 1.68 0.0
well055 0.00184 0.017 3.13E-5 1.68 0.0
well056 0.00184 0.017 3.13E-5 1.68 0.0
well057 0.00184 0.017 3.13E-5 1.68 0.0
well058 0.00184 0.017 3.13E-5 1.68 0.0
well059 0.00184 0.017 3.13E-5 1.68 0.0
well060 0.00184 0.017 3.13E-5 1.68 0.0
well061 0.00184 0.017 3.13E-5 1.68 0.0
well062 0.00184 0.017 3.13E-5 1.68 0.0
well063 0.00184 0.017 3.13E-5 1.68 0.0
well064 0.00184 0.017 3.13E-5 1.68 0.0
well065 0.00184 0.017 3.13E-5 1.68 0.0
well066 0.00184 0.017 3.13E-5 1.68 0.0
well067 0.00184 0.017 3.13E-5 1.68 0.0
well068 0.00184 0.017 3.13E-5 1.68 0.0
well069 0.00184 0.017 3.13E-5 1.68 0.0
well070 0.00184 0.017 3.13E-5 1.68 0.0
well071 0.00184 0.017 3.13E-5 1.68 0.0
well072 0.00184 0.017 3.13E-5 1.68 0.0
well073 0.00184 0.017 3.13E-5 1.68 0.0
well074 0.00184 0.017 3.13E-5 1.68 0.0
well081 0.00184 0.017 3.13E-5 1.68 0.0
well082 0.00184 0.017 3.13E-5 1.68 0.0
well083 0.00184 0.017 3.13E-5 1.68 0.0
well084 0.00184 0.017 3.13E-5 1.68 0.0
well085 0.00184 0.017 3.13E-5 1.68 0.0
well086 0.00184 0.017 3.13E-5 1.68 0.0
well087 0.00184 0.017 3.13E-5 1.68 0.0
well088 0.00184 0.017 3.13E-5 1.68 0.0
well089 0.00184 0.017 3.13E-5 1.68 0.0
well090 0.00184 0.017 3.13E-5 1.68 0.0
well091 0.00184 0.017 3.13E-5 1.68 0.0
well092 0.00184 0.017 3.13E-5 1.68 0.0
well093 0.00184 0.017 3.13E-5 1.68 0.0
well094 0.00184 0.017 3.13E-5 1.68 0.0
well095 0.00184 0.017 3.13E-5 1.68 0.0
well096 0.00184 0.017 3.13E-5 1.68 0.0
well097 0.00184 0.017 3.13E-5 1.68 0.0
well098 0.00184 0.017 3.13E-5 1.68 0.0
well099 0.00184 0.017 3.13E-5 1.68 0.0
well100 0.00184 0.017 3.13E-5 1.68 0.0
well101 0.00184 0.017 3.13E-5 1.68 0.0
well102 0.00184 0.017 3.13E-5 1.68 0.0
well103 0.00184 0.017 3.13E-5 1.68 0.0
well104 0.00184 0.017 3.13E-5 1.68 0.0
well105 0.00184 0.017 3.13E-5 1.68 0.0
upstream 0.0454 1.68 2.7

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:850 (model units)
available capacity:850 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The field1 loss analysis. The losses are relative to the field1 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
wells 828 0 22 850 97.4 97.4
separation 849 0 0.682 850 99.9 99.9
field1 827 0 22.6 850 97.3 97.3

The field1 criticality ranking. The losses are relative to the field1 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 3.64E-16 850 3.1E-13 850 0.0
other 2.22E-12 680 1.51E-9 850 0.0
other 1.14E-43 595 6.7E-41 850 0.0
other 9.13E-42 578 5.28E-39 850 0.0
other 6.67E-40 561 3.74E-37 850 0.0
other 4.47E-38 544 2.43E-35 850 0.0
other 2.75E-36 527 1.45E-33 850 0.0
other 5.39E-9 510 2.75E-6 850 0.0
other 8.12E-33 493 4.0E-30 850 0.0
other 3.91E-31 476 1.86E-28 850 0.0
other 1.74E-29 459 7.98E-27 850 0.0
other 7.14E-28 442 3.16E-25 850 0.0
other 2.71E-26 425 1.15E-23 850 0.0
other 9.53E-25 408 3.89E-22 850 0.0
other 3.1E-23 391 1.21E-20 850 0.0
other 9.29E-22 374 3.47E-19 850 0.0
other 2.57E-20 357 9.19E-18 850 0.0
other 6.57E-6 340 0.00223 850 0.0
other 1.55E-17 323 5.01E-15 850 0.0
other 3.36E-16 306 1.03E-13 850 0.0
other 6.7E-15 289 1.94E-12 850 0.0
other 1.22E-13 272 3.33E-11 850 0.0
other 2.05E-12 255 5.22E-10 850 0.0
other 3.11E-11 238 7.41E-9 850 0.0
other 4.3E-10 221 9.51E-8 850 0.0
other 5.38E-9 204 1.1E-6 850 0.0
other 6.05E-8 187 1.13E-5 850 0.0
other 0.004 170 0.679 850 0.1
other 5.39E-6 153 8.25E-4 850 0.0
other 4.22E-5 136 0.00574 850 0.0
other 2.87E-4 119 0.0342 850 0.0
other 0.00167 102 0.17 850 0.0
other 0.00814 85 0.692 850 0.1
other 0.0324 68 2.2 850 0.3
other 0.101 51 5.14 850 0.6
other 0.23 34 7.83 850 0.9
well001 0.0069 17 0.117 850 0.0
well002 0.0069 17 0.117 850 0.0
well003 0.0069 17 0.117 850 0.0
well004 0.0069 17 0.117 850 0.0
well005 0.0069 17 0.117 850 0.0
well006 0.0069 17 0.117 850 0.0
well007 0.0069 17 0.117 850 0.0
well008 0.0069 17 0.117 850 0.0
well009 0.0069 17 0.117 850 0.0
well010 0.0069 17 0.117 850 0.0
well011 0.0069 17 0.117 850 0.0
well012 0.0069 17 0.117 850 0.0
well013 0.0069 17 0.117 850 0.0
well014 0.0069 17 0.117 850 0.0
well015 0.0069 17 0.117 850 0.0
well016 0.0069 17 0.117 850 0.0
well017 0.0069 17 0.117 850 0.0
well018 0.0069 17 0.117 850 0.0
well019 0.0069 17 0.117 850 0.0
well020 0.0069 17 0.117 850 0.0
well021 0.0069 17 0.117 850 0.0
well022 0.0069 17 0.117 850 0.0
well023 0.0069 17 0.117 850 0.0
well024 0.0069 17 0.117 850 0.0
well025 0.0069 17 0.117 850 0.0
well026 0.0069 17 0.117 850 0.0
well027 0.0069 17 0.117 850 0.0
well028 0.0069 17 0.117 850 0.0
well029 0.0069 17 0.117 850 0.0
well030 0.0069 17 0.117 850 0.0
well031 0.0069 17 0.117 850 0.0
well032 0.0069 17 0.117 850 0.0
well033 0.0069 17 0.117 850 0.0
well034 0.0069 17 0.117 850 0.0
well035 0.0069 17 0.117 850 0.0
well036 0.0069 17 0.117 850 0.0
well037 0.0069 17 0.117 850 0.0
well038 0.0069 17 0.117 850 0.0
well039 0.0069 17 0.117 850 0.0
well040 0.0069 17 0.117 850 0.0
well041 0.0069 17 0.117 850 0.0
well042 0.0069 17 0.117 850 0.0
well043 0.0069 17 0.117 850 0.0
well044 0.0069 17 0.117 850 0.0
well045 0.0069 17 0.117 850 0.0
well046 0.0069 17 0.117 850 0.0
well047 0.0069 17 0.117 850 0.0
well048 0.0069 17 0.117 850 0.0
well049 0.0069 17 0.117 850 0.0
well050 0.0069 17 0.117 850 0.0
field1 22.6 850 2.7

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:850 (model units)
available capacity:850 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The wells loss analysis. The losses are relative to the wells maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
zone1 166 0 4.41 170 97.4 97.4
zone2 166 0 4.41 170 97.4 97.4
zone3 166 0 4.41 170 97.4 97.4
zone4 166 0 4.41 170 97.4 97.4
zone5 166 0 4.41 170 97.4 97.4
wells 828 0 22 850 97.4 97.4

The wells criticality ranking. The losses are relative to the wells maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 1.14E-43 595 6.73E-41 850 0.0
other 9.13E-42 578 5.28E-39 850 0.0
other 6.67E-40 561 3.74E-37 850 0.0
other 4.47E-38 544 2.43E-35 850 0.0
other 2.75E-36 527 1.45E-33 850 0.0
other 1.56E-34 510 7.93E-32 850 0.0
other 8.12E-33 493 4.0E-30 850 0.0
other 3.91E-31 476 1.86E-28 850 0.0
other 1.74E-29 459 7.98E-27 850 0.0
other 7.14E-28 442 3.16E-25 850 0.0
other 2.71E-26 425 1.15E-23 850 0.0
other 9.53E-25 408 3.89E-22 850 0.0
other 3.1E-23 391 1.21E-20 850 0.0
other 9.29E-22 374 3.47E-19 850 0.0
other 2.57E-20 357 9.19E-18 850 0.0
other 6.58E-19 340 2.24E-16 850 0.0
other 1.55E-17 323 5.01E-15 850 0.0
other 3.36E-16 306 1.03E-13 850 0.0
other 6.7E-15 289 1.94E-12 850 0.0
other 1.22E-13 272 3.33E-11 850 0.0
other 2.05E-12 255 5.22E-10 850 0.0
other 3.11E-11 238 7.41E-9 850 0.0
other 4.3E-10 221 9.51E-8 850 0.0
other 5.38E-9 204 1.1E-6 850 0.0
other 6.05E-8 187 1.13E-5 850 0.0
other 6.08E-7 170 1.03E-4 850 0.0
other 5.42E-6 153 8.29E-4 850 0.0
other 4.24E-5 136 0.00577 850 0.0
other 2.88E-4 119 0.0343 850 0.0
other 0.00168 102 0.171 850 0.0
other 0.00817 85 0.695 850 0.1
other 0.0325 68 2.21 850 0.3
other 0.101 51 5.16 850 0.6
other 0.231 34 7.87 850 0.9
well001 0.00692 17 0.118 850 0.0
well002 0.00692 17 0.118 850 0.0
well003 0.00692 17 0.118 850 0.0
well004 0.00692 17 0.118 850 0.0
well005 0.00692 17 0.118 850 0.0
well006 0.00692 17 0.118 850 0.0
well007 0.00692 17 0.118 850 0.0
well008 0.00692 17 0.118 850 0.0
well009 0.00692 17 0.118 850 0.0
well010 0.00692 17 0.118 850 0.0
well011 0.00692 17 0.118 850 0.0
well012 0.00692 17 0.118 850 0.0
well013 0.00692 17 0.118 850 0.0
well014 0.00692 17 0.118 850 0.0
well015 0.00692 17 0.118 850 0.0
well016 0.00692 17 0.118 850 0.0
well017 0.00692 17 0.118 850 0.0
well018 0.00692 17 0.118 850 0.0
well019 0.00692 17 0.118 850 0.0
well020 0.00692 17 0.118 850 0.0
well021 0.00692 17 0.118 850 0.0
well022 0.00692 17 0.118 850 0.0
well023 0.00692 17 0.118 850 0.0
well024 0.00692 17 0.118 850 0.0
well025 0.00692 17 0.118 850 0.0
well026 0.00692 17 0.118 850 0.0
well027 0.00692 17 0.118 850 0.0
well028 0.00692 17 0.118 850 0.0
well029 0.00692 17 0.118 850 0.0
well030 0.00692 17 0.118 850 0.0
well031 0.00692 17 0.118 850 0.0
well032 0.00692 17 0.118 850 0.0
well033 0.00692 17 0.118 850 0.0
well034 0.00692 17 0.118 850 0.0
well035 0.00692 17 0.118 850 0.0
well036 0.00692 17 0.118 850 0.0
well037 0.00692 17 0.118 850 0.0
well038 0.00692 17 0.118 850 0.0
well039 0.00692 17 0.118 850 0.0
well040 0.00692 17 0.118 850 0.0
well041 0.00692 17 0.118 850 0.0
well042 0.00692 17 0.118 850 0.0
well043 0.00692 17 0.118 850 0.0
well044 0.00692 17 0.118 850 0.0
well045 0.00692 17 0.118 850 0.0
well046 0.00692 17 0.118 850 0.0
well047 0.00692 17 0.118 850 0.0
well048 0.00692 17 0.118 850 0.0
well049 0.00692 17 0.118 850 0.0
well050 0.00692 17 0.118 850 0.0
wells 22 850 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The zone1 loss analysis. The losses are relative to the zone1 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well001 16.6 0 0.441 17 97.4 97.4
well002 16.6 0 0.441 17 97.4 97.4
well003 16.6 0 0.441 17 97.4 97.4
well004 16.6 0 0.441 17 97.4 97.4
well005 16.6 0 0.441 17 97.4 97.4
well006 16.6 0 0.441 17 97.4 97.4
well007 16.6 0 0.441 17 97.4 97.4
well008 16.6 0 0.441 17 97.4 97.4
well009 16.6 0 0.441 17 97.4 97.4
well010 16.6 0 0.441 17 97.4 97.4
zone1 166 0 4.41 170 97.4 97.4

The zone1 criticality ranking. The losses are relative to the zone1 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 1.74E-16 170 2.96E-14 170 0.0
other 6.37E-14 153 9.74E-12 170 0.0
other 1.05E-11 136 1.42E-9 170 0.0
other 1.02E-9 119 1.21E-7 170 0.0
other 6.52E-8 102 6.65E-6 170 0.0
other 2.86E-6 85 2.43E-4 170 0.0
other 8.72E-5 68 0.00593 170 0.0
other 0.00182 51 0.0929 170 0.1
+ ( well001 well002) 5.55E-4 34 0.0189 170 0.0
+ ( well001 well003) 5.55E-4 34 0.0189 170 0.0
+ ( well001 well004) 5.55E-4 34 0.0189 170 0.0
+ ( well001 well005) 5.55E-4 34 0.0189 170 0.0
+ ( well001 well006) 5.55E-4 34 0.0189 170 0.0
+ ( well001 well007) 5.55E-4 34 0.0189 170 0.0
+ ( well001 well008) 5.55E-4 34 0.0189 170 0.0
+ ( well001 well009) 5.55E-4 34 0.0189 170 0.0
+ ( well001 well010) 5.55E-4 34 0.0189 170 0.0
+ ( well002 well003) 5.55E-4 34 0.0189 170 0.0
+ ( well002 well004) 5.55E-4 34 0.0189 170 0.0
+ ( well002 well005) 5.55E-4 34 0.0189 170 0.0
+ ( well002 well006) 5.55E-4 34 0.0189 170 0.0
+ ( well002 well007) 5.55E-4 34 0.0189 170 0.0
+ ( well002 well008) 5.55E-4 34 0.0189 170 0.0
+ ( well002 well009) 5.55E-4 34 0.0189 170 0.0
+ ( well002 well010) 5.55E-4 34 0.0189 170 0.0
+ ( well003 well004) 5.55E-4 34 0.0189 170 0.0
+ ( well003 well005) 5.55E-4 34 0.0189 170 0.0
+ ( well003 well006) 5.55E-4 34 0.0189 170 0.0
+ ( well003 well007) 5.55E-4 34 0.0189 170 0.0
+ ( well003 well008) 5.55E-4 34 0.0189 170 0.0
+ ( well003 well009) 5.55E-4 34 0.0189 170 0.0
+ ( well003 well010) 5.55E-4 34 0.0189 170 0.0
+ ( well004 well005) 5.55E-4 34 0.0189 170 0.0
+ ( well004 well006) 5.55E-4 34 0.0189 170 0.0
+ ( well004 well007) 5.55E-4 34 0.0189 170 0.0
+ ( well004 well008) 5.55E-4 34 0.0189 170 0.0
+ ( well004 well009) 5.55E-4 34 0.0189 170 0.0
+ ( well004 well010) 5.55E-4 34 0.0189 170 0.0
+ ( well005 well006) 5.55E-4 34 0.0189 170 0.0
+ ( well005 well007) 5.55E-4 34 0.0189 170 0.0
+ ( well005 well008) 5.55E-4 34 0.0189 170 0.0
+ ( well005 well009) 5.55E-4 34 0.0189 170 0.0
+ ( well005 well010) 5.55E-4 34 0.0189 170 0.0
+ ( well006 well007) 5.55E-4 34 0.0189 170 0.0
+ ( well006 well008) 5.55E-4 34 0.0189 170 0.0
+ ( well006 well009) 5.55E-4 34 0.0189 170 0.0
+ ( well006 well010) 5.55E-4 34 0.0189 170 0.0
+ ( well007 well008) 5.55E-4 34 0.0189 170 0.0
+ ( well007 well009) 5.55E-4 34 0.0189 170 0.0
+ ( well007 well010) 5.55E-4 34 0.0189 170 0.0
+ ( well008 well009) 5.55E-4 34 0.0189 170 0.0
+ ( well008 well010) 5.55E-4 34 0.0189 170 0.0
+ ( well009 well010) 5.55E-4 34 0.0189 170 0.0
well001 0.0203 17 0.346 170 0.2
well002 0.0203 17 0.346 170 0.2
well003 0.0203 17 0.346 170 0.2
well004 0.0203 17 0.346 170 0.2
well005 0.0203 17 0.346 170 0.2
well006 0.0203 17 0.346 170 0.2
well007 0.0203 17 0.346 170 0.2
well008 0.0203 17 0.346 170 0.2
well009 0.0203 17 0.346 170 0.2
well010 0.0203 17 0.346 170 0.2
zone1 4.41 170 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well001 loss analysis. The losses are relative to the well001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well001 16.6 0 0.441 17 97.4 97.4

The well001 criticality ranking. The losses are relative to the well001 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well001 0.0259 17 0.441 17 2.6
well001 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well002 loss analysis. The losses are relative to the well002 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well002 16.6 0 0.441 17 97.4 97.4

The well002 criticality ranking. The losses are relative to the well002 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well002 0.0259 17 0.441 17 2.6
well002 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well003 loss analysis. The losses are relative to the well003 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well003 16.6 0 0.441 17 97.4 97.4

The well003 criticality ranking. The losses are relative to the well003 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well003 0.0259 17 0.441 17 2.6
well003 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well004 loss analysis. The losses are relative to the well004 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well004 16.6 0 0.441 17 97.4 97.4

The well004 criticality ranking. The losses are relative to the well004 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well004 0.0259 17 0.441 17 2.6
well004 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well005 loss analysis. The losses are relative to the well005 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well005 16.6 0 0.441 17 97.4 97.4

The well005 criticality ranking. The losses are relative to the well005 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well005 0.0259 17 0.441 17 2.6
well005 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well006 loss analysis. The losses are relative to the well006 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well006 16.6 0 0.441 17 97.4 97.4

The well006 criticality ranking. The losses are relative to the well006 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well006 0.0259 17 0.441 17 2.6
well006 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well007 loss analysis. The losses are relative to the well007 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well007 16.6 0 0.441 17 97.4 97.4

The well007 criticality ranking. The losses are relative to the well007 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well007 0.0259 17 0.441 17 2.6
well007 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well008 loss analysis. The losses are relative to the well008 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well008 16.6 0 0.441 17 97.4 97.4

The well008 criticality ranking. The losses are relative to the well008 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well008 0.0259 17 0.441 17 2.6
well008 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well009 loss analysis. The losses are relative to the well009 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well009 16.6 0 0.441 17 97.4 97.4

The well009 criticality ranking. The losses are relative to the well009 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well009 0.0259 17 0.441 17 2.6
well009 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well010 loss analysis. The losses are relative to the well010 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well010 16.6 0 0.441 17 97.4 97.4

The well010 criticality ranking. The losses are relative to the well010 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well010 0.0259 17 0.441 17 2.6
well010 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The zone2 loss analysis. The losses are relative to the zone2 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well011 16.6 0 0.441 17 97.4 97.4
well012 16.6 0 0.441 17 97.4 97.4
well013 16.6 0 0.441 17 97.4 97.4
well014 16.6 0 0.441 17 97.4 97.4
well015 16.6 0 0.441 17 97.4 97.4
well016 16.6 0 0.441 17 97.4 97.4
well017 16.6 0 0.441 17 97.4 97.4
well018 16.6 0 0.441 17 97.4 97.4
well019 16.6 0 0.441 17 97.4 97.4
well020 16.6 0 0.441 17 97.4 97.4
zone2 166 0 4.41 170 97.4 97.4

The zone2 criticality ranking. The losses are relative to the zone2 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 1.74E-16 170 2.96E-14 170 0.0
other 6.37E-14 153 9.74E-12 170 0.0
other 1.05E-11 136 1.42E-9 170 0.0
other 1.02E-9 119 1.21E-7 170 0.0
other 6.52E-8 102 6.65E-6 170 0.0
other 2.86E-6 85 2.43E-4 170 0.0
other 8.72E-5 68 0.00593 170 0.0
other 0.00182 51 0.0929 170 0.1
+ ( well011 well012) 5.55E-4 34 0.0189 170 0.0
+ ( well011 well013) 5.55E-4 34 0.0189 170 0.0
+ ( well011 well014) 5.55E-4 34 0.0189 170 0.0
+ ( well011 well015) 5.55E-4 34 0.0189 170 0.0
+ ( well011 well016) 5.55E-4 34 0.0189 170 0.0
+ ( well011 well017) 5.55E-4 34 0.0189 170 0.0
+ ( well011 well018) 5.55E-4 34 0.0189 170 0.0
+ ( well011 well019) 5.55E-4 34 0.0189 170 0.0
+ ( well011 well020) 5.55E-4 34 0.0189 170 0.0
+ ( well012 well013) 5.55E-4 34 0.0189 170 0.0
+ ( well012 well014) 5.55E-4 34 0.0189 170 0.0
+ ( well012 well015) 5.55E-4 34 0.0189 170 0.0
+ ( well012 well016) 5.55E-4 34 0.0189 170 0.0
+ ( well012 well017) 5.55E-4 34 0.0189 170 0.0
+ ( well012 well018) 5.55E-4 34 0.0189 170 0.0
+ ( well012 well019) 5.55E-4 34 0.0189 170 0.0
+ ( well012 well020) 5.55E-4 34 0.0189 170 0.0
+ ( well013 well014) 5.55E-4 34 0.0189 170 0.0
+ ( well013 well015) 5.55E-4 34 0.0189 170 0.0
+ ( well013 well016) 5.55E-4 34 0.0189 170 0.0
+ ( well013 well017) 5.55E-4 34 0.0189 170 0.0
+ ( well013 well018) 5.55E-4 34 0.0189 170 0.0
+ ( well013 well019) 5.55E-4 34 0.0189 170 0.0
+ ( well013 well020) 5.55E-4 34 0.0189 170 0.0
+ ( well014 well015) 5.55E-4 34 0.0189 170 0.0
+ ( well014 well016) 5.55E-4 34 0.0189 170 0.0
+ ( well014 well017) 5.55E-4 34 0.0189 170 0.0
+ ( well014 well018) 5.55E-4 34 0.0189 170 0.0
+ ( well014 well019) 5.55E-4 34 0.0189 170 0.0
+ ( well014 well020) 5.55E-4 34 0.0189 170 0.0
+ ( well015 well016) 5.55E-4 34 0.0189 170 0.0
+ ( well015 well017) 5.55E-4 34 0.0189 170 0.0
+ ( well015 well018) 5.55E-4 34 0.0189 170 0.0
+ ( well015 well019) 5.55E-4 34 0.0189 170 0.0
+ ( well015 well020) 5.55E-4 34 0.0189 170 0.0
+ ( well016 well017) 5.55E-4 34 0.0189 170 0.0
+ ( well016 well018) 5.55E-4 34 0.0189 170 0.0
+ ( well016 well019) 5.55E-4 34 0.0189 170 0.0
+ ( well016 well020) 5.55E-4 34 0.0189 170 0.0
+ ( well017 well018) 5.55E-4 34 0.0189 170 0.0
+ ( well017 well019) 5.55E-4 34 0.0189 170 0.0
+ ( well017 well020) 5.55E-4 34 0.0189 170 0.0
+ ( well018 well019) 5.55E-4 34 0.0189 170 0.0
+ ( well018 well020) 5.55E-4 34 0.0189 170 0.0
+ ( well019 well020) 5.55E-4 34 0.0189 170 0.0
well011 0.0203 17 0.346 170 0.2
well012 0.0203 17 0.346 170 0.2
well013 0.0203 17 0.346 170 0.2
well014 0.0203 17 0.346 170 0.2
well015 0.0203 17 0.346 170 0.2
well016 0.0203 17 0.346 170 0.2
well017 0.0203 17 0.346 170 0.2
well018 0.0203 17 0.346 170 0.2
well019 0.0203 17 0.346 170 0.2
well020 0.0203 17 0.346 170 0.2
zone2 4.41 170 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well011 loss analysis. The losses are relative to the well011 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well011 16.6 0 0.441 17 97.4 97.4

The well011 criticality ranking. The losses are relative to the well011 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well011 0.0259 17 0.441 17 2.6
well011 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well012 loss analysis. The losses are relative to the well012 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well012 16.6 0 0.441 17 97.4 97.4

The well012 criticality ranking. The losses are relative to the well012 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well012 0.0259 17 0.441 17 2.6
well012 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well013 loss analysis. The losses are relative to the well013 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well013 16.6 0 0.441 17 97.4 97.4

The well013 criticality ranking. The losses are relative to the well013 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well013 0.0259 17 0.441 17 2.6
well013 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well014 loss analysis. The losses are relative to the well014 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well014 16.6 0 0.441 17 97.4 97.4

The well014 criticality ranking. The losses are relative to the well014 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well014 0.0259 17 0.441 17 2.6
well014 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well015 loss analysis. The losses are relative to the well015 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well015 16.6 0 0.441 17 97.4 97.4

The well015 criticality ranking. The losses are relative to the well015 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well015 0.0259 17 0.441 17 2.6
well015 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well016 loss analysis. The losses are relative to the well016 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well016 16.6 0 0.441 17 97.4 97.4

The well016 criticality ranking. The losses are relative to the well016 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well016 0.0259 17 0.441 17 2.6
well016 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well017 loss analysis. The losses are relative to the well017 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well017 16.6 0 0.441 17 97.4 97.4

The well017 criticality ranking. The losses are relative to the well017 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well017 0.0259 17 0.441 17 2.6
well017 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well018 loss analysis. The losses are relative to the well018 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well018 16.6 0 0.441 17 97.4 97.4

The well018 criticality ranking. The losses are relative to the well018 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well018 0.0259 17 0.441 17 2.6
well018 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well019 loss analysis. The losses are relative to the well019 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well019 16.6 0 0.441 17 97.4 97.4

The well019 criticality ranking. The losses are relative to the well019 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well019 0.0259 17 0.441 17 2.6
well019 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well020 loss analysis. The losses are relative to the well020 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well020 16.6 0 0.441 17 97.4 97.4

The well020 criticality ranking. The losses are relative to the well020 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well020 0.0259 17 0.441 17 2.6
well020 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The zone3 loss analysis. The losses are relative to the zone3 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well021 16.6 0 0.441 17 97.4 97.4
well022 16.6 0 0.441 17 97.4 97.4
well023 16.6 0 0.441 17 97.4 97.4
well024 16.6 0 0.441 17 97.4 97.4
well025 16.6 0 0.441 17 97.4 97.4
well026 16.6 0 0.441 17 97.4 97.4
well027 16.6 0 0.441 17 97.4 97.4
well028 16.6 0 0.441 17 97.4 97.4
well029 16.6 0 0.441 17 97.4 97.4
well030 16.6 0 0.441 17 97.4 97.4
zone3 166 0 4.41 170 97.4 97.4

The zone3 criticality ranking. The losses are relative to the zone3 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 1.74E-16 170 2.96E-14 170 0.0
other 6.37E-14 153 9.74E-12 170 0.0
other 1.05E-11 136 1.42E-9 170 0.0
other 1.02E-9 119 1.21E-7 170 0.0
other 6.52E-8 102 6.65E-6 170 0.0
other 2.86E-6 85 2.43E-4 170 0.0
other 8.72E-5 68 0.00593 170 0.0
other 0.00182 51 0.0929 170 0.1
+ ( well021 well022) 5.55E-4 34 0.0189 170 0.0
+ ( well021 well023) 5.55E-4 34 0.0189 170 0.0
+ ( well021 well024) 5.55E-4 34 0.0189 170 0.0
+ ( well021 well025) 5.55E-4 34 0.0189 170 0.0
+ ( well021 well026) 5.55E-4 34 0.0189 170 0.0
+ ( well021 well027) 5.55E-4 34 0.0189 170 0.0
+ ( well021 well028) 5.55E-4 34 0.0189 170 0.0
+ ( well021 well029) 5.55E-4 34 0.0189 170 0.0
+ ( well021 well030) 5.55E-4 34 0.0189 170 0.0
+ ( well022 well023) 5.55E-4 34 0.0189 170 0.0
+ ( well022 well024) 5.55E-4 34 0.0189 170 0.0
+ ( well022 well025) 5.55E-4 34 0.0189 170 0.0
+ ( well022 well026) 5.55E-4 34 0.0189 170 0.0
+ ( well022 well027) 5.55E-4 34 0.0189 170 0.0
+ ( well022 well028) 5.55E-4 34 0.0189 170 0.0
+ ( well022 well029) 5.55E-4 34 0.0189 170 0.0
+ ( well022 well030) 5.55E-4 34 0.0189 170 0.0
+ ( well023 well024) 5.55E-4 34 0.0189 170 0.0
+ ( well023 well025) 5.55E-4 34 0.0189 170 0.0
+ ( well023 well026) 5.55E-4 34 0.0189 170 0.0
+ ( well023 well027) 5.55E-4 34 0.0189 170 0.0
+ ( well023 well028) 5.55E-4 34 0.0189 170 0.0
+ ( well023 well029) 5.55E-4 34 0.0189 170 0.0
+ ( well023 well030) 5.55E-4 34 0.0189 170 0.0
+ ( well024 well025) 5.55E-4 34 0.0189 170 0.0
+ ( well024 well026) 5.55E-4 34 0.0189 170 0.0
+ ( well024 well027) 5.55E-4 34 0.0189 170 0.0
+ ( well024 well028) 5.55E-4 34 0.0189 170 0.0
+ ( well024 well029) 5.55E-4 34 0.0189 170 0.0
+ ( well024 well030) 5.55E-4 34 0.0189 170 0.0
+ ( well025 well026) 5.55E-4 34 0.0189 170 0.0
+ ( well025 well027) 5.55E-4 34 0.0189 170 0.0
+ ( well025 well028) 5.55E-4 34 0.0189 170 0.0
+ ( well025 well029) 5.55E-4 34 0.0189 170 0.0
+ ( well025 well030) 5.55E-4 34 0.0189 170 0.0
+ ( well026 well027) 5.55E-4 34 0.0189 170 0.0
+ ( well026 well028) 5.55E-4 34 0.0189 170 0.0
+ ( well026 well029) 5.55E-4 34 0.0189 170 0.0
+ ( well026 well030) 5.55E-4 34 0.0189 170 0.0
+ ( well027 well028) 5.55E-4 34 0.0189 170 0.0
+ ( well027 well029) 5.55E-4 34 0.0189 170 0.0
+ ( well027 well030) 5.55E-4 34 0.0189 170 0.0
+ ( well028 well029) 5.55E-4 34 0.0189 170 0.0
+ ( well028 well030) 5.55E-4 34 0.0189 170 0.0
+ ( well029 well030) 5.55E-4 34 0.0189 170 0.0
well021 0.0203 17 0.346 170 0.2
well022 0.0203 17 0.346 170 0.2
well023 0.0203 17 0.346 170 0.2
well024 0.0203 17 0.346 170 0.2
well025 0.0203 17 0.346 170 0.2
well026 0.0203 17 0.346 170 0.2
well027 0.0203 17 0.346 170 0.2
well028 0.0203 17 0.346 170 0.2
well029 0.0203 17 0.346 170 0.2
well030 0.0203 17 0.346 170 0.2
zone3 4.41 170 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well021 loss analysis. The losses are relative to the well021 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well021 16.6 0 0.441 17 97.4 97.4

The well021 criticality ranking. The losses are relative to the well021 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well021 0.0259 17 0.441 17 2.6
well021 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well022 loss analysis. The losses are relative to the well022 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well022 16.6 0 0.441 17 97.4 97.4

The well022 criticality ranking. The losses are relative to the well022 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well022 0.0259 17 0.441 17 2.6
well022 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well023 loss analysis. The losses are relative to the well023 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well023 16.6 0 0.441 17 97.4 97.4

The well023 criticality ranking. The losses are relative to the well023 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well023 0.0259 17 0.441 17 2.6
well023 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well024 loss analysis. The losses are relative to the well024 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well024 16.6 0 0.441 17 97.4 97.4

The well024 criticality ranking. The losses are relative to the well024 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well024 0.0259 17 0.441 17 2.6
well024 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well025 loss analysis. The losses are relative to the well025 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well025 16.6 0 0.441 17 97.4 97.4

The well025 criticality ranking. The losses are relative to the well025 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well025 0.0259 17 0.441 17 2.6
well025 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well026 loss analysis. The losses are relative to the well026 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well026 16.6 0 0.441 17 97.4 97.4

The well026 criticality ranking. The losses are relative to the well026 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well026 0.0259 17 0.441 17 2.6
well026 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well027 loss analysis. The losses are relative to the well027 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well027 16.6 0 0.441 17 97.4 97.4

The well027 criticality ranking. The losses are relative to the well027 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well027 0.0259 17 0.441 17 2.6
well027 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well028 loss analysis. The losses are relative to the well028 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well028 16.6 0 0.441 17 97.4 97.4

The well028 criticality ranking. The losses are relative to the well028 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well028 0.0259 17 0.441 17 2.6
well028 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well029 loss analysis. The losses are relative to the well029 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well029 16.6 0 0.441 17 97.4 97.4

The well029 criticality ranking. The losses are relative to the well029 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well029 0.0259 17 0.441 17 2.6
well029 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well030 loss analysis. The losses are relative to the well030 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well030 16.6 0 0.441 17 97.4 97.4

The well030 criticality ranking. The losses are relative to the well030 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well030 0.0259 17 0.441 17 2.6
well030 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The zone4 loss analysis. The losses are relative to the zone4 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well031 16.6 0 0.441 17 97.4 97.4
well032 16.6 0 0.441 17 97.4 97.4
well033 16.6 0 0.441 17 97.4 97.4
well034 16.6 0 0.441 17 97.4 97.4
well035 16.6 0 0.441 17 97.4 97.4
well036 16.6 0 0.441 17 97.4 97.4
well037 16.6 0 0.441 17 97.4 97.4
well038 16.6 0 0.441 17 97.4 97.4
well039 16.6 0 0.441 17 97.4 97.4
well040 16.6 0 0.441 17 97.4 97.4
zone4 166 0 4.41 170 97.4 97.4

The zone4 criticality ranking. The losses are relative to the zone4 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 1.74E-16 170 2.96E-14 170 0.0
other 6.37E-14 153 9.74E-12 170 0.0
other 1.05E-11 136 1.42E-9 170 0.0
other 1.02E-9 119 1.21E-7 170 0.0
other 6.52E-8 102 6.65E-6 170 0.0
other 2.86E-6 85 2.43E-4 170 0.0
other 8.72E-5 68 0.00593 170 0.0
other 0.00182 51 0.0929 170 0.1
+ ( well031 well032) 5.55E-4 34 0.0189 170 0.0
+ ( well031 well033) 5.55E-4 34 0.0189 170 0.0
+ ( well031 well034) 5.55E-4 34 0.0189 170 0.0
+ ( well031 well035) 5.55E-4 34 0.0189 170 0.0
+ ( well031 well036) 5.55E-4 34 0.0189 170 0.0
+ ( well031 well037) 5.55E-4 34 0.0189 170 0.0
+ ( well031 well038) 5.55E-4 34 0.0189 170 0.0
+ ( well031 well039) 5.55E-4 34 0.0189 170 0.0
+ ( well031 well040) 5.55E-4 34 0.0189 170 0.0
+ ( well032 well033) 5.55E-4 34 0.0189 170 0.0
+ ( well032 well034) 5.55E-4 34 0.0189 170 0.0
+ ( well032 well035) 5.55E-4 34 0.0189 170 0.0
+ ( well032 well036) 5.55E-4 34 0.0189 170 0.0
+ ( well032 well037) 5.55E-4 34 0.0189 170 0.0
+ ( well032 well038) 5.55E-4 34 0.0189 170 0.0
+ ( well032 well039) 5.55E-4 34 0.0189 170 0.0
+ ( well032 well040) 5.55E-4 34 0.0189 170 0.0
+ ( well033 well034) 5.55E-4 34 0.0189 170 0.0
+ ( well033 well035) 5.55E-4 34 0.0189 170 0.0
+ ( well033 well036) 5.55E-4 34 0.0189 170 0.0
+ ( well033 well037) 5.55E-4 34 0.0189 170 0.0
+ ( well033 well038) 5.55E-4 34 0.0189 170 0.0
+ ( well033 well039) 5.55E-4 34 0.0189 170 0.0
+ ( well033 well040) 5.55E-4 34 0.0189 170 0.0
+ ( well034 well035) 5.55E-4 34 0.0189 170 0.0
+ ( well034 well036) 5.55E-4 34 0.0189 170 0.0
+ ( well034 well037) 5.55E-4 34 0.0189 170 0.0
+ ( well034 well038) 5.55E-4 34 0.0189 170 0.0
+ ( well034 well039) 5.55E-4 34 0.0189 170 0.0
+ ( well034 well040) 5.55E-4 34 0.0189 170 0.0
+ ( well035 well036) 5.55E-4 34 0.0189 170 0.0
+ ( well035 well037) 5.55E-4 34 0.0189 170 0.0
+ ( well035 well038) 5.55E-4 34 0.0189 170 0.0
+ ( well035 well039) 5.55E-4 34 0.0189 170 0.0
+ ( well035 well040) 5.55E-4 34 0.0189 170 0.0
+ ( well036 well037) 5.55E-4 34 0.0189 170 0.0
+ ( well036 well038) 5.55E-4 34 0.0189 170 0.0
+ ( well036 well039) 5.55E-4 34 0.0189 170 0.0
+ ( well036 well040) 5.55E-4 34 0.0189 170 0.0
+ ( well037 well038) 5.55E-4 34 0.0189 170 0.0
+ ( well037 well039) 5.55E-4 34 0.0189 170 0.0
+ ( well037 well040) 5.55E-4 34 0.0189 170 0.0
+ ( well038 well039) 5.55E-4 34 0.0189 170 0.0
+ ( well038 well040) 5.55E-4 34 0.0189 170 0.0
+ ( well039 well040) 5.55E-4 34 0.0189 170 0.0
well031 0.0203 17 0.346 170 0.2
well032 0.0203 17 0.346 170 0.2
well033 0.0203 17 0.346 170 0.2
well034 0.0203 17 0.346 170 0.2
well035 0.0203 17 0.346 170 0.2
well036 0.0203 17 0.346 170 0.2
well037 0.0203 17 0.346 170 0.2
well038 0.0203 17 0.346 170 0.2
well039 0.0203 17 0.346 170 0.2
well040 0.0203 17 0.346 170 0.2
zone4 4.41 170 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well031 loss analysis. The losses are relative to the well031 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well031 16.6 0 0.441 17 97.4 97.4

The well031 criticality ranking. The losses are relative to the well031 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well031 0.0259 17 0.441 17 2.6
well031 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well032 loss analysis. The losses are relative to the well032 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well032 16.6 0 0.441 17 97.4 97.4

The well032 criticality ranking. The losses are relative to the well032 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well032 0.0259 17 0.441 17 2.6
well032 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well033 loss analysis. The losses are relative to the well033 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well033 16.6 0 0.441 17 97.4 97.4

The well033 criticality ranking. The losses are relative to the well033 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well033 0.0259 17 0.441 17 2.6
well033 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well034 loss analysis. The losses are relative to the well034 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well034 16.6 0 0.441 17 97.4 97.4

The well034 criticality ranking. The losses are relative to the well034 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well034 0.0259 17 0.441 17 2.6
well034 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well035 loss analysis. The losses are relative to the well035 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well035 16.6 0 0.441 17 97.4 97.4

The well035 criticality ranking. The losses are relative to the well035 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well035 0.0259 17 0.441 17 2.6
well035 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well036 loss analysis. The losses are relative to the well036 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well036 16.6 0 0.441 17 97.4 97.4

The well036 criticality ranking. The losses are relative to the well036 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well036 0.0259 17 0.441 17 2.6
well036 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well037 loss analysis. The losses are relative to the well037 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well037 16.6 0 0.441 17 97.4 97.4

The well037 criticality ranking. The losses are relative to the well037 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well037 0.0259 17 0.441 17 2.6
well037 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well038 loss analysis. The losses are relative to the well038 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well038 16.6 0 0.441 17 97.4 97.4

The well038 criticality ranking. The losses are relative to the well038 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well038 0.0259 17 0.441 17 2.6
well038 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well039 loss analysis. The losses are relative to the well039 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well039 16.6 0 0.441 17 97.4 97.4

The well039 criticality ranking. The losses are relative to the well039 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well039 0.0259 17 0.441 17 2.6
well039 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well040 loss analysis. The losses are relative to the well040 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well040 16.6 0 0.441 17 97.4 97.4

The well040 criticality ranking. The losses are relative to the well040 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well040 0.0259 17 0.441 17 2.6
well040 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The zone5 loss analysis. The losses are relative to the zone5 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well041 16.6 0 0.441 17 97.4 97.4
well042 16.6 0 0.441 17 97.4 97.4
well043 16.6 0 0.441 17 97.4 97.4
well044 16.6 0 0.441 17 97.4 97.4
well045 16.6 0 0.441 17 97.4 97.4
well046 16.6 0 0.441 17 97.4 97.4
well047 16.6 0 0.441 17 97.4 97.4
well048 16.6 0 0.441 17 97.4 97.4
well049 16.6 0 0.441 17 97.4 97.4
well050 16.6 0 0.441 17 97.4 97.4
zone5 166 0 4.41 170 97.4 97.4

The zone5 criticality ranking. The losses are relative to the zone5 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 1.74E-16 170 2.96E-14 170 0.0
other 6.37E-14 153 9.74E-12 170 0.0
other 1.05E-11 136 1.42E-9 170 0.0
other 1.02E-9 119 1.21E-7 170 0.0
other 6.52E-8 102 6.65E-6 170 0.0
other 2.86E-6 85 2.43E-4 170 0.0
other 8.72E-5 68 0.00593 170 0.0
other 0.00182 51 0.0929 170 0.1
+ ( well041 well042) 5.55E-4 34 0.0189 170 0.0
+ ( well041 well043) 5.55E-4 34 0.0189 170 0.0
+ ( well041 well044) 5.55E-4 34 0.0189 170 0.0
+ ( well041 well045) 5.55E-4 34 0.0189 170 0.0
+ ( well041 well046) 5.55E-4 34 0.0189 170 0.0
+ ( well041 well047) 5.55E-4 34 0.0189 170 0.0
+ ( well041 well048) 5.55E-4 34 0.0189 170 0.0
+ ( well041 well049) 5.55E-4 34 0.0189 170 0.0
+ ( well041 well050) 5.55E-4 34 0.0189 170 0.0
+ ( well042 well043) 5.55E-4 34 0.0189 170 0.0
+ ( well042 well044) 5.55E-4 34 0.0189 170 0.0
+ ( well042 well045) 5.55E-4 34 0.0189 170 0.0
+ ( well042 well046) 5.55E-4 34 0.0189 170 0.0
+ ( well042 well047) 5.55E-4 34 0.0189 170 0.0
+ ( well042 well048) 5.55E-4 34 0.0189 170 0.0
+ ( well042 well049) 5.55E-4 34 0.0189 170 0.0
+ ( well042 well050) 5.55E-4 34 0.0189 170 0.0
+ ( well043 well044) 5.55E-4 34 0.0189 170 0.0
+ ( well043 well045) 5.55E-4 34 0.0189 170 0.0
+ ( well043 well046) 5.55E-4 34 0.0189 170 0.0
+ ( well043 well047) 5.55E-4 34 0.0189 170 0.0
+ ( well043 well048) 5.55E-4 34 0.0189 170 0.0
+ ( well043 well049) 5.55E-4 34 0.0189 170 0.0
+ ( well043 well050) 5.55E-4 34 0.0189 170 0.0
+ ( well044 well045) 5.55E-4 34 0.0189 170 0.0
+ ( well044 well046) 5.55E-4 34 0.0189 170 0.0
+ ( well044 well047) 5.55E-4 34 0.0189 170 0.0
+ ( well044 well048) 5.55E-4 34 0.0189 170 0.0
+ ( well044 well049) 5.55E-4 34 0.0189 170 0.0
+ ( well044 well050) 5.55E-4 34 0.0189 170 0.0
+ ( well045 well046) 5.55E-4 34 0.0189 170 0.0
+ ( well045 well047) 5.55E-4 34 0.0189 170 0.0
+ ( well045 well048) 5.55E-4 34 0.0189 170 0.0
+ ( well045 well049) 5.55E-4 34 0.0189 170 0.0
+ ( well045 well050) 5.55E-4 34 0.0189 170 0.0
+ ( well046 well047) 5.55E-4 34 0.0189 170 0.0
+ ( well046 well048) 5.55E-4 34 0.0189 170 0.0
+ ( well046 well049) 5.55E-4 34 0.0189 170 0.0
+ ( well046 well050) 5.55E-4 34 0.0189 170 0.0
+ ( well047 well048) 5.55E-4 34 0.0189 170 0.0
+ ( well047 well049) 5.55E-4 34 0.0189 170 0.0
+ ( well047 well050) 5.55E-4 34 0.0189 170 0.0
+ ( well048 well049) 5.55E-4 34 0.0189 170 0.0
+ ( well048 well050) 5.55E-4 34 0.0189 170 0.0
+ ( well049 well050) 5.55E-4 34 0.0189 170 0.0
well041 0.0203 17 0.346 170 0.2
well042 0.0203 17 0.346 170 0.2
well043 0.0203 17 0.346 170 0.2
well044 0.0203 17 0.346 170 0.2
well045 0.0203 17 0.346 170 0.2
well046 0.0203 17 0.346 170 0.2
well047 0.0203 17 0.346 170 0.2
well048 0.0203 17 0.346 170 0.2
well049 0.0203 17 0.346 170 0.2
well050 0.0203 17 0.346 170 0.2
zone5 4.41 170 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well041 loss analysis. The losses are relative to the well041 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well041 16.6 0 0.441 17 97.4 97.4

The well041 criticality ranking. The losses are relative to the well041 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well041 0.0259 17 0.441 17 2.6
well041 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well042 loss analysis. The losses are relative to the well042 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well042 16.6 0 0.441 17 97.4 97.4

The well042 criticality ranking. The losses are relative to the well042 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well042 0.0259 17 0.441 17 2.6
well042 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well043 loss analysis. The losses are relative to the well043 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well043 16.6 0 0.441 17 97.4 97.4

The well043 criticality ranking. The losses are relative to the well043 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well043 0.0259 17 0.441 17 2.6
well043 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well044 loss analysis. The losses are relative to the well044 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well044 16.6 0 0.441 17 97.4 97.4

The well044 criticality ranking. The losses are relative to the well044 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well044 0.0259 17 0.441 17 2.6
well044 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well045 loss analysis. The losses are relative to the well045 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well045 16.6 0 0.441 17 97.4 97.4

The well045 criticality ranking. The losses are relative to the well045 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well045 0.0259 17 0.441 17 2.6
well045 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well046 loss analysis. The losses are relative to the well046 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well046 16.6 0 0.441 17 97.4 97.4

The well046 criticality ranking. The losses are relative to the well046 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well046 0.0259 17 0.441 17 2.6
well046 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well047 loss analysis. The losses are relative to the well047 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well047 16.6 0 0.441 17 97.4 97.4

The well047 criticality ranking. The losses are relative to the well047 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well047 0.0259 17 0.441 17 2.6
well047 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well048 loss analysis. The losses are relative to the well048 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well048 16.6 0 0.441 17 97.4 97.4

The well048 criticality ranking. The losses are relative to the well048 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well048 0.0259 17 0.441 17 2.6
well048 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well049 loss analysis. The losses are relative to the well049 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well049 16.6 0 0.441 17 97.4 97.4

The well049 criticality ranking. The losses are relative to the well049 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well049 0.0259 17 0.441 17 2.6
well049 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well050 loss analysis. The losses are relative to the well050 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well050 16.6 0 0.441 17 97.4 97.4

The well050 criticality ranking. The losses are relative to the well050 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well050 0.0259 17 0.441 17 2.6
well050 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:850 (model units)
available capacity:850 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The separation loss analysis. The losses are relative to the separation maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
train1 170 0 0.136 170 99.9 99.9
train2 170 0 0.136 170 99.9 99.9
train3 170 0 0.136 170 99.9 99.9
train4 170 0 0.136 170 99.9 99.9
train5 170 0 0.136 170 99.9 99.9
separation 849 0 0.682 850 99.9 99.9

The separation criticality ranking. The losses are relative to the separation maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 3.64E-16 850 3.1E-13 850 0.0
other 2.22E-12 680 1.51E-9 850 0.0
other 5.39E-9 510 2.75E-6 850 0.0
other 6.57E-6 340 0.00223 850 0.0
other 0.004 170 0.679 850 0.1
separation 0.682 850 0.1

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The train1 loss analysis. The losses are relative to the train1 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V1001 170 0 0.0455 170 100.0 100.0
V1002 170 0 0.0455 170 100.0 100.0
V1003 170 0 0.0455 170 100.0 100.0
train1 170 0 0.136 170 99.9 99.9

The train1 criticality ranking. The losses are relative to the train1 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 8.02E-4 170 0.136 170 0.1
train1 0.136 170 0.1

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V1001 loss analysis. The losses are relative to the V1001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V1001 170 0 0.0455 170 100.0 100.0

The V1001 criticality ranking. The losses are relative to the V1001 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V1001 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V1002 loss analysis. The losses are relative to the V1002 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V1002 170 0 0.0455 170 100.0 100.0

The V1002 criticality ranking. The losses are relative to the V1002 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V1002 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V1003 loss analysis. The losses are relative to the V1003 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V1003 170 0 0.0455 170 100.0 100.0

The V1003 criticality ranking. The losses are relative to the V1003 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V1003 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The train2 loss analysis. The losses are relative to the train2 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V2001 170 0 0.0455 170 100.0 100.0
V2002 170 0 0.0455 170 100.0 100.0
V2003 170 0 0.0455 170 100.0 100.0
train2 170 0 0.136 170 99.9 99.9

The train2 criticality ranking. The losses are relative to the train2 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 8.02E-4 170 0.136 170 0.1
train2 0.136 170 0.1

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V2001 loss analysis. The losses are relative to the V2001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V2001 170 0 0.0455 170 100.0 100.0

The V2001 criticality ranking. The losses are relative to the V2001 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V2001 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V2002 loss analysis. The losses are relative to the V2002 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V2002 170 0 0.0455 170 100.0 100.0

The V2002 criticality ranking. The losses are relative to the V2002 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V2002 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V2003 loss analysis. The losses are relative to the V2003 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V2003 170 0 0.0455 170 100.0 100.0

The V2003 criticality ranking. The losses are relative to the V2003 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V2003 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The train3 loss analysis. The losses are relative to the train3 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V3001 170 0 0.0455 170 100.0 100.0
V3002 170 0 0.0455 170 100.0 100.0
V3003 170 0 0.0455 170 100.0 100.0
train3 170 0 0.136 170 99.9 99.9

The train3 criticality ranking. The losses are relative to the train3 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 8.02E-4 170 0.136 170 0.1
train3 0.136 170 0.1

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V3001 loss analysis. The losses are relative to the V3001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V3001 170 0 0.0455 170 100.0 100.0

The V3001 criticality ranking. The losses are relative to the V3001 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V3001 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V3002 loss analysis. The losses are relative to the V3002 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V3002 170 0 0.0455 170 100.0 100.0

The V3002 criticality ranking. The losses are relative to the V3002 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V3002 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V3003 loss analysis. The losses are relative to the V3003 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V3003 170 0 0.0455 170 100.0 100.0

The V3003 criticality ranking. The losses are relative to the V3003 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V3003 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The train4 loss analysis. The losses are relative to the train4 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V4001 170 0 0.0455 170 100.0 100.0
V4002 170 0 0.0455 170 100.0 100.0
V4003 170 0 0.0455 170 100.0 100.0
train4 170 0 0.136 170 99.9 99.9

The train4 criticality ranking. The losses are relative to the train4 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 8.02E-4 170 0.136 170 0.1
train4 0.136 170 0.1

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V4001 loss analysis. The losses are relative to the V4001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V4001 170 0 0.0455 170 100.0 100.0

The V4001 criticality ranking. The losses are relative to the V4001 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V4001 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V4002 loss analysis. The losses are relative to the V4002 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V4002 170 0 0.0455 170 100.0 100.0

The V4002 criticality ranking. The losses are relative to the V4002 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V4002 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V4003 loss analysis. The losses are relative to the V4003 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V4003 170 0 0.0455 170 100.0 100.0

The V4003 criticality ranking. The losses are relative to the V4003 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V4003 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The train5 loss analysis. The losses are relative to the train5 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V5001 170 0 0.0455 170 100.0 100.0
V5002 170 0 0.0455 170 100.0 100.0
V5003 170 0 0.0455 170 100.0 100.0
train5 170 0 0.136 170 99.9 99.9

The train5 criticality ranking. The losses are relative to the train5 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 8.02E-4 170 0.136 170 0.1
train5 0.136 170 0.1

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V5001 loss analysis. The losses are relative to the V5001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V5001 170 0 0.0455 170 100.0 100.0

The V5001 criticality ranking. The losses are relative to the V5001 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V5001 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V5002 loss analysis. The losses are relative to the V5002 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V5002 170 0 0.0455 170 100.0 100.0

The V5002 criticality ranking. The losses are relative to the V5002 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V5002 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V5003 loss analysis. The losses are relative to the V5003 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V5003 170 0 0.0455 170 100.0 100.0

The V5003 criticality ranking. The losses are relative to the V5003 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V5003 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:408 (model units)
available capacity:408 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The field2 loss analysis. The losses are relative to the field2 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
wells 397 0 10.6 408 97.4 97.4
separation 407 0 1.09 408 99.7 99.7
field2 396 0 11.6 408 97.1 97.1

The field2 criticality ranking. The losses are relative to the field2 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 5.4E-10 408 2.2E-7 408 0.0
other 1.39E-35 391 5.43E-33 408 0.0
other 5.83E-33 374 2.18E-30 408 0.0
other 1.56E-30 357 5.57E-28 408 0.0
other 2.99E-28 340 1.02E-25 408 0.0
other 4.38E-26 323 1.41E-23 408 0.0
other 5.06E-24 306 1.55E-21 408 0.0
other 4.76E-22 289 1.37E-19 408 0.0
other 3.69E-20 272 1.0E-17 408 0.0
other 2.4E-18 255 6.11E-16 408 0.0
other 1.97E-6 238 4.7E-4 408 0.0
other 6.11E-15 221 1.35E-12 408 0.0
other 2.42E-13 204 4.93E-11 408 0.0
other 8.16E-12 187 1.53E-9 408 0.0
other 2.34E-10 170 3.98E-8 408 0.0
other 5.7E-9 153 8.73E-7 408 0.0
other 1.17E-7 136 1.59E-5 408 0.0
other 2.02E-6 119 2.4E-4 408 0.0
other 2.87E-5 102 0.00292 408 0.0
other 3.31E-4 85 0.0281 408 0.0
⊥ ( V6001 ⊥ ( V6002 V6003)) 0.0137 68 0.931 408 0.2
other 0.00542 68 0.368 408 0.1
other 0.021 51 1.07 408 0.3
other 0.105 34 3.56 408 0.9
well051 0.0139 17 0.236 408 0.1
well052 0.0139 17 0.236 408 0.1
well053 0.0139 17 0.236 408 0.1
well054 0.0139 17 0.236 408 0.1
well055 0.0139 17 0.236 408 0.1
well056 0.0139 17 0.236 408 0.1
well057 0.0139 17 0.236 408 0.1
well058 0.0139 17 0.236 408 0.1
well059 0.0139 17 0.236 408 0.1
well060 0.0139 17 0.236 408 0.1
well061 0.0139 17 0.236 408 0.1
well062 0.0139 17 0.236 408 0.1
well063 0.0139 17 0.236 408 0.1
well064 0.0139 17 0.236 408 0.1
well065 0.0139 17 0.236 408 0.1
well066 0.0139 17 0.236 408 0.1
well067 0.0139 17 0.236 408 0.1
well068 0.0139 17 0.236 408 0.1
well069 0.0139 17 0.236 408 0.1
well070 0.0139 17 0.236 408 0.1
well071 0.0139 17 0.236 408 0.1
well072 0.0139 17 0.236 408 0.1
well073 0.0139 17 0.236 408 0.1
well074 0.0139 17 0.236 408 0.1
field2 11.6 408 2.9

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:408 (model units)
available capacity:408 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The wells loss analysis. The losses are relative to the wells maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
zone1 166 0 4.41 170 97.4 97.4
zone2 166 0 4.41 170 97.4 97.4
zone3 66.2 0 1.76 68 97.4 97.4
wells 397 0 10.6 408 97.4 97.4

The wells criticality ranking. The losses are relative to the wells maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 1.58E-38 408 6.46E-36 408 0.0
other 1.39E-35 391 5.43E-33 408 0.0
other 5.83E-33 374 2.18E-30 408 0.0
other 1.56E-30 357 5.57E-28 408 0.0
other 2.99E-28 340 1.02E-25 408 0.0
other 4.38E-26 323 1.41E-23 408 0.0
other 5.06E-24 306 1.55E-21 408 0.0
other 4.76E-22 289 1.37E-19 408 0.0
other 3.69E-20 272 1.0E-17 408 0.0
other 2.4E-18 255 6.11E-16 408 0.0
other 1.31E-16 238 3.13E-14 408 0.0
other 6.11E-15 221 1.35E-12 408 0.0
other 2.42E-13 204 4.93E-11 408 0.0
other 8.16E-12 187 1.53E-9 408 0.0
other 2.34E-10 170 3.98E-8 408 0.0
other 5.7E-9 153 8.73E-7 408 0.0
other 1.17E-7 136 1.59E-5 408 0.0
other 2.02E-6 119 2.4E-4 408 0.0
other 2.87E-5 102 0.00292 408 0.0
other 3.31E-4 85 0.0281 408 0.0
other 0.00302 68 0.206 408 0.1
other 0.0211 51 1.07 408 0.3
other 0.105 34 3.57 408 0.9
well051 0.0139 17 0.237 408 0.1
well052 0.0139 17 0.237 408 0.1
well053 0.0139 17 0.237 408 0.1
well054 0.0139 17 0.237 408 0.1
well055 0.0139 17 0.237 408 0.1
well056 0.0139 17 0.237 408 0.1
well057 0.0139 17 0.237 408 0.1
well058 0.0139 17 0.237 408 0.1
well059 0.0139 17 0.237 408 0.1
well060 0.0139 17 0.237 408 0.1
well061 0.0139 17 0.237 408 0.1
well062 0.0139 17 0.237 408 0.1
well063 0.0139 17 0.237 408 0.1
well064 0.0139 17 0.237 408 0.1
well065 0.0139 17 0.237 408 0.1
well066 0.0139 17 0.237 408 0.1
well067 0.0139 17 0.237 408 0.1
well068 0.0139 17 0.237 408 0.1
well069 0.0139 17 0.237 408 0.1
well070 0.0139 17 0.237 408 0.1
well071 0.0139 17 0.237 408 0.1
well072 0.0139 17 0.237 408 0.1
well073 0.0139 17 0.237 408 0.1
well074 0.0139 17 0.237 408 0.1
wells 10.6 408 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The zone1 loss analysis. The losses are relative to the zone1 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well051 16.6 0 0.441 17 97.4 97.4
well052 16.6 0 0.441 17 97.4 97.4
well053 16.6 0 0.441 17 97.4 97.4
well054 16.6 0 0.441 17 97.4 97.4
well055 16.6 0 0.441 17 97.4 97.4
well056 16.6 0 0.441 17 97.4 97.4
well057 16.6 0 0.441 17 97.4 97.4
well058 16.6 0 0.441 17 97.4 97.4
well059 16.6 0 0.441 17 97.4 97.4
well060 16.6 0 0.441 17 97.4 97.4
zone1 166 0 4.41 170 97.4 97.4

The zone1 criticality ranking. The losses are relative to the zone1 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 1.74E-16 170 2.96E-14 170 0.0
other 6.37E-14 153 9.74E-12 170 0.0
other 1.05E-11 136 1.42E-9 170 0.0
other 1.02E-9 119 1.21E-7 170 0.0
other 6.52E-8 102 6.65E-6 170 0.0
other 2.86E-6 85 2.43E-4 170 0.0
other 8.72E-5 68 0.00593 170 0.0
other 0.00182 51 0.0929 170 0.1
+ ( well051 well052) 5.55E-4 34 0.0189 170 0.0
+ ( well051 well053) 5.55E-4 34 0.0189 170 0.0
+ ( well051 well054) 5.55E-4 34 0.0189 170 0.0
+ ( well051 well055) 5.55E-4 34 0.0189 170 0.0
+ ( well051 well056) 5.55E-4 34 0.0189 170 0.0
+ ( well051 well057) 5.55E-4 34 0.0189 170 0.0
+ ( well051 well058) 5.55E-4 34 0.0189 170 0.0
+ ( well051 well059) 5.55E-4 34 0.0189 170 0.0
+ ( well051 well060) 5.55E-4 34 0.0189 170 0.0
+ ( well052 well053) 5.55E-4 34 0.0189 170 0.0
+ ( well052 well054) 5.55E-4 34 0.0189 170 0.0
+ ( well052 well055) 5.55E-4 34 0.0189 170 0.0
+ ( well052 well056) 5.55E-4 34 0.0189 170 0.0
+ ( well052 well057) 5.55E-4 34 0.0189 170 0.0
+ ( well052 well058) 5.55E-4 34 0.0189 170 0.0
+ ( well052 well059) 5.55E-4 34 0.0189 170 0.0
+ ( well052 well060) 5.55E-4 34 0.0189 170 0.0
+ ( well053 well054) 5.55E-4 34 0.0189 170 0.0
+ ( well053 well055) 5.55E-4 34 0.0189 170 0.0
+ ( well053 well056) 5.55E-4 34 0.0189 170 0.0
+ ( well053 well057) 5.55E-4 34 0.0189 170 0.0
+ ( well053 well058) 5.55E-4 34 0.0189 170 0.0
+ ( well053 well059) 5.55E-4 34 0.0189 170 0.0
+ ( well053 well060) 5.55E-4 34 0.0189 170 0.0
+ ( well054 well055) 5.55E-4 34 0.0189 170 0.0
+ ( well054 well056) 5.55E-4 34 0.0189 170 0.0
+ ( well054 well057) 5.55E-4 34 0.0189 170 0.0
+ ( well054 well058) 5.55E-4 34 0.0189 170 0.0
+ ( well054 well059) 5.55E-4 34 0.0189 170 0.0
+ ( well054 well060) 5.55E-4 34 0.0189 170 0.0
+ ( well055 well056) 5.55E-4 34 0.0189 170 0.0
+ ( well055 well057) 5.55E-4 34 0.0189 170 0.0
+ ( well055 well058) 5.55E-4 34 0.0189 170 0.0
+ ( well055 well059) 5.55E-4 34 0.0189 170 0.0
+ ( well055 well060) 5.55E-4 34 0.0189 170 0.0
+ ( well056 well057) 5.55E-4 34 0.0189 170 0.0
+ ( well056 well058) 5.55E-4 34 0.0189 170 0.0
+ ( well056 well059) 5.55E-4 34 0.0189 170 0.0
+ ( well056 well060) 5.55E-4 34 0.0189 170 0.0
+ ( well057 well058) 5.55E-4 34 0.0189 170 0.0
+ ( well057 well059) 5.55E-4 34 0.0189 170 0.0
+ ( well057 well060) 5.55E-4 34 0.0189 170 0.0
+ ( well058 well059) 5.55E-4 34 0.0189 170 0.0
+ ( well058 well060) 5.55E-4 34 0.0189 170 0.0
+ ( well059 well060) 5.55E-4 34 0.0189 170 0.0
well051 0.0203 17 0.346 170 0.2
well052 0.0203 17 0.346 170 0.2
well053 0.0203 17 0.346 170 0.2
well054 0.0203 17 0.346 170 0.2
well055 0.0203 17 0.346 170 0.2
well056 0.0203 17 0.346 170 0.2
well057 0.0203 17 0.346 170 0.2
well058 0.0203 17 0.346 170 0.2
well059 0.0203 17 0.346 170 0.2
well060 0.0203 17 0.346 170 0.2
zone1 4.41 170 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well051 loss analysis. The losses are relative to the well051 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well051 16.6 0 0.441 17 97.4 97.4

The well051 criticality ranking. The losses are relative to the well051 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well051 0.0259 17 0.441 17 2.6
well051 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well052 loss analysis. The losses are relative to the well052 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well052 16.6 0 0.441 17 97.4 97.4

The well052 criticality ranking. The losses are relative to the well052 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well052 0.0259 17 0.441 17 2.6
well052 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well053 loss analysis. The losses are relative to the well053 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well053 16.6 0 0.441 17 97.4 97.4

The well053 criticality ranking. The losses are relative to the well053 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well053 0.0259 17 0.441 17 2.6
well053 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well054 loss analysis. The losses are relative to the well054 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well054 16.6 0 0.441 17 97.4 97.4

The well054 criticality ranking. The losses are relative to the well054 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well054 0.0259 17 0.441 17 2.6
well054 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well055 loss analysis. The losses are relative to the well055 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well055 16.6 0 0.441 17 97.4 97.4

The well055 criticality ranking. The losses are relative to the well055 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well055 0.0259 17 0.441 17 2.6
well055 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well056 loss analysis. The losses are relative to the well056 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well056 16.6 0 0.441 17 97.4 97.4

The well056 criticality ranking. The losses are relative to the well056 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well056 0.0259 17 0.441 17 2.6
well056 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well057 loss analysis. The losses are relative to the well057 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well057 16.6 0 0.441 17 97.4 97.4

The well057 criticality ranking. The losses are relative to the well057 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well057 0.0259 17 0.441 17 2.6
well057 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well058 loss analysis. The losses are relative to the well058 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well058 16.6 0 0.441 17 97.4 97.4

The well058 criticality ranking. The losses are relative to the well058 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well058 0.0259 17 0.441 17 2.6
well058 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well059 loss analysis. The losses are relative to the well059 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well059 16.6 0 0.441 17 97.4 97.4

The well059 criticality ranking. The losses are relative to the well059 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well059 0.0259 17 0.441 17 2.6
well059 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well060 loss analysis. The losses are relative to the well060 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well060 16.6 0 0.441 17 97.4 97.4

The well060 criticality ranking. The losses are relative to the well060 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well060 0.0259 17 0.441 17 2.6
well060 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The zone2 loss analysis. The losses are relative to the zone2 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well061 16.6 0 0.441 17 97.4 97.4
well062 16.6 0 0.441 17 97.4 97.4
well063 16.6 0 0.441 17 97.4 97.4
well064 16.6 0 0.441 17 97.4 97.4
well065 16.6 0 0.441 17 97.4 97.4
well066 16.6 0 0.441 17 97.4 97.4
well067 16.6 0 0.441 17 97.4 97.4
well068 16.6 0 0.441 17 97.4 97.4
well069 16.6 0 0.441 17 97.4 97.4
well070 16.6 0 0.441 17 97.4 97.4
zone2 166 0 4.41 170 97.4 97.4

The zone2 criticality ranking. The losses are relative to the zone2 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 1.74E-16 170 2.96E-14 170 0.0
other 6.37E-14 153 9.74E-12 170 0.0
other 1.05E-11 136 1.42E-9 170 0.0
other 1.02E-9 119 1.21E-7 170 0.0
other 6.52E-8 102 6.65E-6 170 0.0
other 2.86E-6 85 2.43E-4 170 0.0
other 8.72E-5 68 0.00593 170 0.0
other 0.00182 51 0.0929 170 0.1
+ ( well061 well062) 5.55E-4 34 0.0189 170 0.0
+ ( well061 well063) 5.55E-4 34 0.0189 170 0.0
+ ( well061 well064) 5.55E-4 34 0.0189 170 0.0
+ ( well061 well065) 5.55E-4 34 0.0189 170 0.0
+ ( well061 well066) 5.55E-4 34 0.0189 170 0.0
+ ( well061 well067) 5.55E-4 34 0.0189 170 0.0
+ ( well061 well068) 5.55E-4 34 0.0189 170 0.0
+ ( well061 well069) 5.55E-4 34 0.0189 170 0.0
+ ( well061 well070) 5.55E-4 34 0.0189 170 0.0
+ ( well062 well063) 5.55E-4 34 0.0189 170 0.0
+ ( well062 well064) 5.55E-4 34 0.0189 170 0.0
+ ( well062 well065) 5.55E-4 34 0.0189 170 0.0
+ ( well062 well066) 5.55E-4 34 0.0189 170 0.0
+ ( well062 well067) 5.55E-4 34 0.0189 170 0.0
+ ( well062 well068) 5.55E-4 34 0.0189 170 0.0
+ ( well062 well069) 5.55E-4 34 0.0189 170 0.0
+ ( well062 well070) 5.55E-4 34 0.0189 170 0.0
+ ( well063 well064) 5.55E-4 34 0.0189 170 0.0
+ ( well063 well065) 5.55E-4 34 0.0189 170 0.0
+ ( well063 well066) 5.55E-4 34 0.0189 170 0.0
+ ( well063 well067) 5.55E-4 34 0.0189 170 0.0
+ ( well063 well068) 5.55E-4 34 0.0189 170 0.0
+ ( well063 well069) 5.55E-4 34 0.0189 170 0.0
+ ( well063 well070) 5.55E-4 34 0.0189 170 0.0
+ ( well064 well065) 5.55E-4 34 0.0189 170 0.0
+ ( well064 well066) 5.55E-4 34 0.0189 170 0.0
+ ( well064 well067) 5.55E-4 34 0.0189 170 0.0
+ ( well064 well068) 5.55E-4 34 0.0189 170 0.0
+ ( well064 well069) 5.55E-4 34 0.0189 170 0.0
+ ( well064 well070) 5.55E-4 34 0.0189 170 0.0
+ ( well065 well066) 5.55E-4 34 0.0189 170 0.0
+ ( well065 well067) 5.55E-4 34 0.0189 170 0.0
+ ( well065 well068) 5.55E-4 34 0.0189 170 0.0
+ ( well065 well069) 5.55E-4 34 0.0189 170 0.0
+ ( well065 well070) 5.55E-4 34 0.0189 170 0.0
+ ( well066 well067) 5.55E-4 34 0.0189 170 0.0
+ ( well066 well068) 5.55E-4 34 0.0189 170 0.0
+ ( well066 well069) 5.55E-4 34 0.0189 170 0.0
+ ( well066 well070) 5.55E-4 34 0.0189 170 0.0
+ ( well067 well068) 5.55E-4 34 0.0189 170 0.0
+ ( well067 well069) 5.55E-4 34 0.0189 170 0.0
+ ( well067 well070) 5.55E-4 34 0.0189 170 0.0
+ ( well068 well069) 5.55E-4 34 0.0189 170 0.0
+ ( well068 well070) 5.55E-4 34 0.0189 170 0.0
+ ( well069 well070) 5.55E-4 34 0.0189 170 0.0
well061 0.0203 17 0.346 170 0.2
well062 0.0203 17 0.346 170 0.2
well063 0.0203 17 0.346 170 0.2
well064 0.0203 17 0.346 170 0.2
well065 0.0203 17 0.346 170 0.2
well066 0.0203 17 0.346 170 0.2
well067 0.0203 17 0.346 170 0.2
well068 0.0203 17 0.346 170 0.2
well069 0.0203 17 0.346 170 0.2
well070 0.0203 17 0.346 170 0.2
zone2 4.41 170 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well061 loss analysis. The losses are relative to the well061 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well061 16.6 0 0.441 17 97.4 97.4

The well061 criticality ranking. The losses are relative to the well061 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well061 0.0259 17 0.441 17 2.6
well061 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well062 loss analysis. The losses are relative to the well062 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well062 16.6 0 0.441 17 97.4 97.4

The well062 criticality ranking. The losses are relative to the well062 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well062 0.0259 17 0.441 17 2.6
well062 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well063 loss analysis. The losses are relative to the well063 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well063 16.6 0 0.441 17 97.4 97.4

The well063 criticality ranking. The losses are relative to the well063 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well063 0.0259 17 0.441 17 2.6
well063 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well064 loss analysis. The losses are relative to the well064 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well064 16.6 0 0.441 17 97.4 97.4

The well064 criticality ranking. The losses are relative to the well064 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well064 0.0259 17 0.441 17 2.6
well064 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well065 loss analysis. The losses are relative to the well065 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well065 16.6 0 0.441 17 97.4 97.4

The well065 criticality ranking. The losses are relative to the well065 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well065 0.0259 17 0.441 17 2.6
well065 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well066 loss analysis. The losses are relative to the well066 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well066 16.6 0 0.441 17 97.4 97.4

The well066 criticality ranking. The losses are relative to the well066 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well066 0.0259 17 0.441 17 2.6
well066 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well067 loss analysis. The losses are relative to the well067 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well067 16.6 0 0.441 17 97.4 97.4

The well067 criticality ranking. The losses are relative to the well067 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well067 0.0259 17 0.441 17 2.6
well067 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well068 loss analysis. The losses are relative to the well068 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well068 16.6 0 0.441 17 97.4 97.4

The well068 criticality ranking. The losses are relative to the well068 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well068 0.0259 17 0.441 17 2.6
well068 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well069 loss analysis. The losses are relative to the well069 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well069 16.6 0 0.441 17 97.4 97.4

The well069 criticality ranking. The losses are relative to the well069 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well069 0.0259 17 0.441 17 2.6
well069 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well070 loss analysis. The losses are relative to the well070 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well070 16.6 0 0.441 17 97.4 97.4

The well070 criticality ranking. The losses are relative to the well070 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well070 0.0259 17 0.441 17 2.6
well070 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:68 (model units)
available capacity:68 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The zone3 loss analysis. The losses are relative to the zone3 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well071 16.6 0 0.441 17 97.4 97.4
well072 16.6 0 0.441 17 97.4 97.4
well073 16.6 0 0.441 17 97.4 97.4
well074 16.6 0 0.441 17 97.4 97.4
zone3 66.2 0 1.76 68 97.4 97.4

The zone3 criticality ranking. The losses are relative to the zone3 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 4.88E-7 68 3.32E-5 68 0.0
other 7.14E-5 51 0.00364 68 0.0
+ ( well071 well072) 6.53E-4 34 0.0222 68 0.0
+ ( well071 well073) 6.53E-4 34 0.0222 68 0.0
+ ( well071 well074) 6.53E-4 34 0.0222 68 0.0
+ ( well072 well073) 6.53E-4 34 0.0222 68 0.0
+ ( well072 well074) 6.53E-4 34 0.0222 68 0.0
+ ( well073 well074) 6.53E-4 34 0.0222 68 0.0
well071 0.0239 17 0.406 68 0.6
well072 0.0239 17 0.406 68 0.6
well073 0.0239 17 0.406 68 0.6
well074 0.0239 17 0.406 68 0.6
zone3 1.76 68 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well071 loss analysis. The losses are relative to the well071 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well071 16.6 0 0.441 17 97.4 97.4

The well071 criticality ranking. The losses are relative to the well071 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well071 0.0259 17 0.441 17 2.6
well071 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well072 loss analysis. The losses are relative to the well072 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well072 16.6 0 0.441 17 97.4 97.4

The well072 criticality ranking. The losses are relative to the well072 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well072 0.0259 17 0.441 17 2.6
well072 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well073 loss analysis. The losses are relative to the well073 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well073 16.6 0 0.441 17 97.4 97.4

The well073 criticality ranking. The losses are relative to the well073 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well073 0.0259 17 0.441 17 2.6
well073 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well074 loss analysis. The losses are relative to the well074 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well074 16.6 0 0.441 17 97.4 97.4

The well074 criticality ranking. The losses are relative to the well074 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well074 0.0259 17 0.441 17 2.6
well074 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:510 (model units)
available capacity:510 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The separation loss analysis. The losses are relative to the separation maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
train1 168 0 2.46 170 98.6 98.6
train2 170 0 0.136 170 99.9 99.9
train3 170 0 0.136 170 99.9 99.9
separation 507 0 2.74 510 99.5 99.5

The separation criticality ranking. The losses are relative to the separation maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 5.4E-10 510 2.76E-7 510 0.0
other 1.97E-6 340 6.71E-4 510 0.0
⊥ ( V6001 ⊥ ( V6002 V6003)) 0.0137 170 2.33 510 0.5
other 0.0024 170 0.408 510 0.1
separation 2.74 510 0.5

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The train1 loss analysis. The losses are relative to the train1 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V6001 168 0 2.37 170 98.6 98.6
V6002 168 0 2.37 170 98.6 98.6
V6003 168 0 2.37 170 98.6 98.6
train1 168 0 2.46 170 98.6 98.6

The train1 criticality ranking. The losses are relative to the train1 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
⊥ ( V6001 ⊥ ( V6002 V6003)) 0.0137 170 2.33 170 1.4
other 8.02E-4 170 0.136 170 0.1
train1 2.46 170 1.4

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V6001 loss analysis. The losses are relative to the V6001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V6001 168 0 2.37 170 98.6 98.6

The V6001 criticality ranking. The losses are relative to the V6001 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
V6001 0.014 170 2.37 170 1.4
V6001 2.37 170 1.4

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V6002 loss analysis. The losses are relative to the V6002 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V6002 168 0 2.37 170 98.6 98.6

The V6002 criticality ranking. The losses are relative to the V6002 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
V6002 0.014 170 2.37 170 1.4
V6002 2.37 170 1.4

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V6003 loss analysis. The losses are relative to the V6003 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V6003 168 0 2.37 170 98.6 98.6

The V6003 criticality ranking. The losses are relative to the V6003 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
V6003 0.014 170 2.37 170 1.4
V6003 2.37 170 1.4

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The train2 loss analysis. The losses are relative to the train2 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V7001 170 0 0.0455 170 100.0 100.0
V7002 170 0 0.0455 170 100.0 100.0
V7003 170 0 0.0455 170 100.0 100.0
train2 170 0 0.136 170 99.9 99.9

The train2 criticality ranking. The losses are relative to the train2 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 8.02E-4 170 0.136 170 0.1
train2 0.136 170 0.1

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V7001 loss analysis. The losses are relative to the V7001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V7001 170 0 0.0455 170 100.0 100.0

The V7001 criticality ranking. The losses are relative to the V7001 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V7001 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V7002 loss analysis. The losses are relative to the V7002 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V7002 170 0 0.0455 170 100.0 100.0

The V7002 criticality ranking. The losses are relative to the V7002 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V7002 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V7003 loss analysis. The losses are relative to the V7003 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V7003 170 0 0.0455 170 100.0 100.0

The V7003 criticality ranking. The losses are relative to the V7003 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V7003 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The train3 loss analysis. The losses are relative to the train3 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V8001 170 0 0.0455 170 100.0 100.0
V8002 170 0 0.0455 170 100.0 100.0
V8003 170 0 0.0455 170 100.0 100.0
train3 170 0 0.136 170 99.9 99.9

The train3 criticality ranking. The losses are relative to the train3 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 8.02E-4 170 0.136 170 0.1
train3 0.136 170 0.1

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V8001 loss analysis. The losses are relative to the V8001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V8001 170 0 0.0455 170 100.0 100.0

The V8001 criticality ranking. The losses are relative to the V8001 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V8001 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V8002 loss analysis. The losses are relative to the V8002 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V8002 170 0 0.0455 170 100.0 100.0

The V8002 criticality ranking. The losses are relative to the V8002 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V8002 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V8003 loss analysis. The losses are relative to the V8003 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V8003 170 0 0.0455 170 100.0 100.0

The V8003 criticality ranking. The losses are relative to the V8003 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V8003 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:425 (model units)
available capacity:425 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The field3 loss analysis. The losses are relative to the field3 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
wells 414 0 11 425 97.4 97.4
separation 425 0 0.205 425 100.0 100.0
field3 414 0 11.2 425 97.4 97.4

The field3 criticality ranking. The losses are relative to the field3 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 5.4E-10 425 2.3E-7 425 0.0
other 3.85E-37 408 1.57E-34 425 0.0
other 1.69E-34 391 6.6E-32 425 0.0
other 4.73E-32 374 1.77E-29 425 0.0
other 9.5E-30 357 3.39E-27 425 0.0
other 1.46E-27 340 4.96E-25 425 0.0
other 1.77E-25 323 5.73E-23 425 0.0
other 1.76E-23 306 5.38E-21 425 0.0
other 1.45E-21 289 4.18E-19 425 0.0
other 9.98E-20 272 2.71E-17 425 0.0
other 1.97E-6 255 5.03E-4 425 0.0
other 2.91E-16 238 6.92E-14 425 0.0
other 1.24E-14 221 2.74E-12 425 0.0
other 4.53E-13 204 9.23E-11 425 0.0
other 1.42E-11 187 2.65E-9 425 0.0
other 3.8E-10 170 6.46E-8 425 0.0
other 8.67E-9 153 1.33E-6 425 0.0
other 1.68E-7 136 2.28E-5 425 0.0
other 2.73E-6 119 3.24E-4 425 0.0
other 3.67E-5 102 0.00374 425 0.0
other 0.0028 85 0.238 425 0.1
other 0.00349 68 0.238 425 0.1
other 0.0232 51 1.19 425 0.3
other 0.111 34 3.77 425 0.9
well081 0.0135 17 0.23 425 0.1
well082 0.0135 17 0.23 425 0.1
well083 0.0135 17 0.23 425 0.1
well084 0.0135 17 0.23 425 0.1
well085 0.0135 17 0.23 425 0.1
well086 0.0135 17 0.23 425 0.1
well087 0.0135 17 0.23 425 0.1
well088 0.0135 17 0.23 425 0.1
well089 0.0135 17 0.23 425 0.1
well090 0.0135 17 0.23 425 0.1
well091 0.0135 17 0.23 425 0.1
well092 0.0135 17 0.23 425 0.1
well093 0.0135 17 0.23 425 0.1
well094 0.0135 17 0.23 425 0.1
well095 0.0135 17 0.23 425 0.1
well096 0.0135 17 0.23 425 0.1
well097 0.0135 17 0.23 425 0.1
well098 0.0135 17 0.23 425 0.1
well099 0.0135 17 0.23 425 0.1
well100 0.0135 17 0.23 425 0.1
well101 0.0135 17 0.23 425 0.1
well102 0.0135 17 0.23 425 0.1
well103 0.0135 17 0.23 425 0.1
well104 0.0135 17 0.23 425 0.1
well105 0.0135 17 0.23 425 0.1
field3 11.2 425 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:425 (model units)
available capacity:425 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The wells loss analysis. The losses are relative to the wells maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
zone1 166 0 4.41 170 97.4 97.4
zone2 166 0 4.41 170 97.4 97.4
zone3 82.8 0 2.2 85 97.4 97.4
wells 414 0 11 425 97.4 97.4

The wells criticality ranking. The losses are relative to the wells maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 4.22E-40 425 1.79E-37 425 0.0
other 3.85E-37 408 1.57E-34 425 0.0
other 1.69E-34 391 6.6E-32 425 0.0
other 4.73E-32 374 1.77E-29 425 0.0
other 9.5E-30 357 3.39E-27 425 0.0
other 1.46E-27 340 4.96E-25 425 0.0
other 1.77E-25 323 5.73E-23 425 0.0
other 1.76E-23 306 5.38E-21 425 0.0
other 1.45E-21 289 4.18E-19 425 0.0
other 9.98E-20 272 2.71E-17 425 0.0
other 5.83E-18 255 1.49E-15 425 0.0
other 2.91E-16 238 6.92E-14 425 0.0
other 1.24E-14 221 2.74E-12 425 0.0
other 4.53E-13 204 9.23E-11 425 0.0
other 1.42E-11 187 2.65E-9 425 0.0
other 3.8E-10 170 6.46E-8 425 0.0
other 8.67E-9 153 1.33E-6 425 0.0
other 1.68E-7 136 2.28E-5 425 0.0
other 2.73E-6 119 3.24E-4 425 0.0
other 3.67E-5 102 0.00374 425 0.0
other 4.02E-4 85 0.0342 425 0.0
other 0.0035 68 0.238 425 0.1
other 0.0233 51 1.19 425 0.3
other 0.111 34 3.78 425 0.9
well081 0.0136 17 0.231 425 0.1
well082 0.0136 17 0.231 425 0.1
well083 0.0136 17 0.231 425 0.1
well084 0.0136 17 0.231 425 0.1
well085 0.0136 17 0.231 425 0.1
well086 0.0136 17 0.231 425 0.1
well087 0.0136 17 0.231 425 0.1
well088 0.0136 17 0.231 425 0.1
well089 0.0136 17 0.231 425 0.1
well090 0.0136 17 0.231 425 0.1
well091 0.0136 17 0.231 425 0.1
well092 0.0136 17 0.231 425 0.1
well093 0.0136 17 0.231 425 0.1
well094 0.0136 17 0.231 425 0.1
well095 0.0136 17 0.231 425 0.1
well096 0.0136 17 0.231 425 0.1
well097 0.0136 17 0.231 425 0.1
well098 0.0136 17 0.231 425 0.1
well099 0.0136 17 0.231 425 0.1
well100 0.0136 17 0.231 425 0.1
well101 0.0136 17 0.231 425 0.1
well102 0.0136 17 0.231 425 0.1
well103 0.0136 17 0.231 425 0.1
well104 0.0136 17 0.231 425 0.1
well105 0.0136 17 0.231 425 0.1
wells 11 425 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The zone1 loss analysis. The losses are relative to the zone1 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well081 16.6 0 0.441 17 97.4 97.4
well082 16.6 0 0.441 17 97.4 97.4
well083 16.6 0 0.441 17 97.4 97.4
well084 16.6 0 0.441 17 97.4 97.4
well085 16.6 0 0.441 17 97.4 97.4
well086 16.6 0 0.441 17 97.4 97.4
well087 16.6 0 0.441 17 97.4 97.4
well088 16.6 0 0.441 17 97.4 97.4
well089 16.6 0 0.441 17 97.4 97.4
well090 16.6 0 0.441 17 97.4 97.4
zone1 166 0 4.41 170 97.4 97.4

The zone1 criticality ranking. The losses are relative to the zone1 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 1.74E-16 170 2.96E-14 170 0.0
other 6.37E-14 153 9.74E-12 170 0.0
other 1.05E-11 136 1.42E-9 170 0.0
other 1.02E-9 119 1.21E-7 170 0.0
other 6.52E-8 102 6.65E-6 170 0.0
other 2.86E-6 85 2.43E-4 170 0.0
other 8.72E-5 68 0.00593 170 0.0
other 0.00182 51 0.0929 170 0.1
+ ( well081 well082) 5.55E-4 34 0.0189 170 0.0
+ ( well081 well083) 5.55E-4 34 0.0189 170 0.0
+ ( well081 well084) 5.55E-4 34 0.0189 170 0.0
+ ( well081 well085) 5.55E-4 34 0.0189 170 0.0
+ ( well081 well086) 5.55E-4 34 0.0189 170 0.0
+ ( well081 well087) 5.55E-4 34 0.0189 170 0.0
+ ( well081 well088) 5.55E-4 34 0.0189 170 0.0
+ ( well081 well089) 5.55E-4 34 0.0189 170 0.0
+ ( well081 well090) 5.55E-4 34 0.0189 170 0.0
+ ( well082 well083) 5.55E-4 34 0.0189 170 0.0
+ ( well082 well084) 5.55E-4 34 0.0189 170 0.0
+ ( well082 well085) 5.55E-4 34 0.0189 170 0.0
+ ( well082 well086) 5.55E-4 34 0.0189 170 0.0
+ ( well082 well087) 5.55E-4 34 0.0189 170 0.0
+ ( well082 well088) 5.55E-4 34 0.0189 170 0.0
+ ( well082 well089) 5.55E-4 34 0.0189 170 0.0
+ ( well082 well090) 5.55E-4 34 0.0189 170 0.0
+ ( well083 well084) 5.55E-4 34 0.0189 170 0.0
+ ( well083 well085) 5.55E-4 34 0.0189 170 0.0
+ ( well083 well086) 5.55E-4 34 0.0189 170 0.0
+ ( well083 well087) 5.55E-4 34 0.0189 170 0.0
+ ( well083 well088) 5.55E-4 34 0.0189 170 0.0
+ ( well083 well089) 5.55E-4 34 0.0189 170 0.0
+ ( well083 well090) 5.55E-4 34 0.0189 170 0.0
+ ( well084 well085) 5.55E-4 34 0.0189 170 0.0
+ ( well084 well086) 5.55E-4 34 0.0189 170 0.0
+ ( well084 well087) 5.55E-4 34 0.0189 170 0.0
+ ( well084 well088) 5.55E-4 34 0.0189 170 0.0
+ ( well084 well089) 5.55E-4 34 0.0189 170 0.0
+ ( well084 well090) 5.55E-4 34 0.0189 170 0.0
+ ( well085 well086) 5.55E-4 34 0.0189 170 0.0
+ ( well085 well087) 5.55E-4 34 0.0189 170 0.0
+ ( well085 well088) 5.55E-4 34 0.0189 170 0.0
+ ( well085 well089) 5.55E-4 34 0.0189 170 0.0
+ ( well085 well090) 5.55E-4 34 0.0189 170 0.0
+ ( well086 well087) 5.55E-4 34 0.0189 170 0.0
+ ( well086 well088) 5.55E-4 34 0.0189 170 0.0
+ ( well086 well089) 5.55E-4 34 0.0189 170 0.0
+ ( well086 well090) 5.55E-4 34 0.0189 170 0.0
+ ( well087 well088) 5.55E-4 34 0.0189 170 0.0
+ ( well087 well089) 5.55E-4 34 0.0189 170 0.0
+ ( well087 well090) 5.55E-4 34 0.0189 170 0.0
+ ( well088 well089) 5.55E-4 34 0.0189 170 0.0
+ ( well088 well090) 5.55E-4 34 0.0189 170 0.0
+ ( well089 well090) 5.55E-4 34 0.0189 170 0.0
well081 0.0203 17 0.346 170 0.2
well082 0.0203 17 0.346 170 0.2
well083 0.0203 17 0.346 170 0.2
well084 0.0203 17 0.346 170 0.2
well085 0.0203 17 0.346 170 0.2
well086 0.0203 17 0.346 170 0.2
well087 0.0203 17 0.346 170 0.2
well088 0.0203 17 0.346 170 0.2
well089 0.0203 17 0.346 170 0.2
well090 0.0203 17 0.346 170 0.2
zone1 4.41 170 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well081 loss analysis. The losses are relative to the well081 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well081 16.6 0 0.441 17 97.4 97.4

The well081 criticality ranking. The losses are relative to the well081 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well081 0.0259 17 0.441 17 2.6
well081 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well082 loss analysis. The losses are relative to the well082 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well082 16.6 0 0.441 17 97.4 97.4

The well082 criticality ranking. The losses are relative to the well082 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well082 0.0259 17 0.441 17 2.6
well082 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well083 loss analysis. The losses are relative to the well083 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well083 16.6 0 0.441 17 97.4 97.4

The well083 criticality ranking. The losses are relative to the well083 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well083 0.0259 17 0.441 17 2.6
well083 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well084 loss analysis. The losses are relative to the well084 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well084 16.6 0 0.441 17 97.4 97.4

The well084 criticality ranking. The losses are relative to the well084 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well084 0.0259 17 0.441 17 2.6
well084 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well085 loss analysis. The losses are relative to the well085 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well085 16.6 0 0.441 17 97.4 97.4

The well085 criticality ranking. The losses are relative to the well085 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well085 0.0259 17 0.441 17 2.6
well085 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well086 loss analysis. The losses are relative to the well086 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well086 16.6 0 0.441 17 97.4 97.4

The well086 criticality ranking. The losses are relative to the well086 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well086 0.0259 17 0.441 17 2.6
well086 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well087 loss analysis. The losses are relative to the well087 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well087 16.6 0 0.441 17 97.4 97.4

The well087 criticality ranking. The losses are relative to the well087 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well087 0.0259 17 0.441 17 2.6
well087 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well088 loss analysis. The losses are relative to the well088 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well088 16.6 0 0.441 17 97.4 97.4

The well088 criticality ranking. The losses are relative to the well088 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well088 0.0259 17 0.441 17 2.6
well088 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well089 loss analysis. The losses are relative to the well089 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well089 16.6 0 0.441 17 97.4 97.4

The well089 criticality ranking. The losses are relative to the well089 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well089 0.0259 17 0.441 17 2.6
well089 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well090 loss analysis. The losses are relative to the well090 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well090 16.6 0 0.441 17 97.4 97.4

The well090 criticality ranking. The losses are relative to the well090 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well090 0.0259 17 0.441 17 2.6
well090 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The zone2 loss analysis. The losses are relative to the zone2 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well091 16.6 0 0.441 17 97.4 97.4
well092 16.6 0 0.441 17 97.4 97.4
well093 16.6 0 0.441 17 97.4 97.4
well094 16.6 0 0.441 17 97.4 97.4
well095 16.6 0 0.441 17 97.4 97.4
well096 16.6 0 0.441 17 97.4 97.4
well097 16.6 0 0.441 17 97.4 97.4
well098 16.6 0 0.441 17 97.4 97.4
well099 16.6 0 0.441 17 97.4 97.4
well100 16.6 0 0.441 17 97.4 97.4
zone2 166 0 4.41 170 97.4 97.4

The zone2 criticality ranking. The losses are relative to the zone2 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 1.74E-16 170 2.96E-14 170 0.0
other 6.37E-14 153 9.74E-12 170 0.0
other 1.05E-11 136 1.42E-9 170 0.0
other 1.02E-9 119 1.21E-7 170 0.0
other 6.52E-8 102 6.65E-6 170 0.0
other 2.86E-6 85 2.43E-4 170 0.0
other 8.72E-5 68 0.00593 170 0.0
other 0.00182 51 0.0929 170 0.1
+ ( well091 well092) 5.55E-4 34 0.0189 170 0.0
+ ( well091 well093) 5.55E-4 34 0.0189 170 0.0
+ ( well091 well094) 5.55E-4 34 0.0189 170 0.0
+ ( well091 well095) 5.55E-4 34 0.0189 170 0.0
+ ( well091 well096) 5.55E-4 34 0.0189 170 0.0
+ ( well091 well097) 5.55E-4 34 0.0189 170 0.0
+ ( well091 well098) 5.55E-4 34 0.0189 170 0.0
+ ( well091 well099) 5.55E-4 34 0.0189 170 0.0
+ ( well091 well100) 5.55E-4 34 0.0189 170 0.0
+ ( well092 well093) 5.55E-4 34 0.0189 170 0.0
+ ( well092 well094) 5.55E-4 34 0.0189 170 0.0
+ ( well092 well095) 5.55E-4 34 0.0189 170 0.0
+ ( well092 well096) 5.55E-4 34 0.0189 170 0.0
+ ( well092 well097) 5.55E-4 34 0.0189 170 0.0
+ ( well092 well098) 5.55E-4 34 0.0189 170 0.0
+ ( well092 well099) 5.55E-4 34 0.0189 170 0.0
+ ( well092 well100) 5.55E-4 34 0.0189 170 0.0
+ ( well093 well094) 5.55E-4 34 0.0189 170 0.0
+ ( well093 well095) 5.55E-4 34 0.0189 170 0.0
+ ( well093 well096) 5.55E-4 34 0.0189 170 0.0
+ ( well093 well097) 5.55E-4 34 0.0189 170 0.0
+ ( well093 well098) 5.55E-4 34 0.0189 170 0.0
+ ( well093 well099) 5.55E-4 34 0.0189 170 0.0
+ ( well093 well100) 5.55E-4 34 0.0189 170 0.0
+ ( well094 well095) 5.55E-4 34 0.0189 170 0.0
+ ( well094 well096) 5.55E-4 34 0.0189 170 0.0
+ ( well094 well097) 5.55E-4 34 0.0189 170 0.0
+ ( well094 well098) 5.55E-4 34 0.0189 170 0.0
+ ( well094 well099) 5.55E-4 34 0.0189 170 0.0
+ ( well094 well100) 5.55E-4 34 0.0189 170 0.0
+ ( well095 well096) 5.55E-4 34 0.0189 170 0.0
+ ( well095 well097) 5.55E-4 34 0.0189 170 0.0
+ ( well095 well098) 5.55E-4 34 0.0189 170 0.0
+ ( well095 well099) 5.55E-4 34 0.0189 170 0.0
+ ( well095 well100) 5.55E-4 34 0.0189 170 0.0
+ ( well096 well097) 5.55E-4 34 0.0189 170 0.0
+ ( well096 well098) 5.55E-4 34 0.0189 170 0.0
+ ( well096 well099) 5.55E-4 34 0.0189 170 0.0
+ ( well096 well100) 5.55E-4 34 0.0189 170 0.0
+ ( well097 well098) 5.55E-4 34 0.0189 170 0.0
+ ( well097 well099) 5.55E-4 34 0.0189 170 0.0
+ ( well097 well100) 5.55E-4 34 0.0189 170 0.0
+ ( well098 well099) 5.55E-4 34 0.0189 170 0.0
+ ( well098 well100) 5.55E-4 34 0.0189 170 0.0
+ ( well099 well100) 5.55E-4 34 0.0189 170 0.0
well091 0.0203 17 0.346 170 0.2
well092 0.0203 17 0.346 170 0.2
well093 0.0203 17 0.346 170 0.2
well094 0.0203 17 0.346 170 0.2
well095 0.0203 17 0.346 170 0.2
well096 0.0203 17 0.346 170 0.2
well097 0.0203 17 0.346 170 0.2
well098 0.0203 17 0.346 170 0.2
well099 0.0203 17 0.346 170 0.2
well100 0.0203 17 0.346 170 0.2
zone2 4.41 170 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well091 loss analysis. The losses are relative to the well091 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well091 16.6 0 0.441 17 97.4 97.4

The well091 criticality ranking. The losses are relative to the well091 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well091 0.0259 17 0.441 17 2.6
well091 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well092 loss analysis. The losses are relative to the well092 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well092 16.6 0 0.441 17 97.4 97.4

The well092 criticality ranking. The losses are relative to the well092 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well092 0.0259 17 0.441 17 2.6
well092 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well093 loss analysis. The losses are relative to the well093 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well093 16.6 0 0.441 17 97.4 97.4

The well093 criticality ranking. The losses are relative to the well093 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well093 0.0259 17 0.441 17 2.6
well093 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well094 loss analysis. The losses are relative to the well094 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well094 16.6 0 0.441 17 97.4 97.4

The well094 criticality ranking. The losses are relative to the well094 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well094 0.0259 17 0.441 17 2.6
well094 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well095 loss analysis. The losses are relative to the well095 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well095 16.6 0 0.441 17 97.4 97.4

The well095 criticality ranking. The losses are relative to the well095 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well095 0.0259 17 0.441 17 2.6
well095 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well096 loss analysis. The losses are relative to the well096 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well096 16.6 0 0.441 17 97.4 97.4

The well096 criticality ranking. The losses are relative to the well096 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well096 0.0259 17 0.441 17 2.6
well096 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well097 loss analysis. The losses are relative to the well097 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well097 16.6 0 0.441 17 97.4 97.4

The well097 criticality ranking. The losses are relative to the well097 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well097 0.0259 17 0.441 17 2.6
well097 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well098 loss analysis. The losses are relative to the well098 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well098 16.6 0 0.441 17 97.4 97.4

The well098 criticality ranking. The losses are relative to the well098 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well098 0.0259 17 0.441 17 2.6
well098 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well099 loss analysis. The losses are relative to the well099 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well099 16.6 0 0.441 17 97.4 97.4

The well099 criticality ranking. The losses are relative to the well099 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well099 0.0259 17 0.441 17 2.6
well099 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well100 loss analysis. The losses are relative to the well100 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well100 16.6 0 0.441 17 97.4 97.4

The well100 criticality ranking. The losses are relative to the well100 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well100 0.0259 17 0.441 17 2.6
well100 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:85 (model units)
available capacity:85 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The zone3 loss analysis. The losses are relative to the zone3 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well101 16.6 0 0.441 17 97.4 97.4
well102 16.6 0 0.441 17 97.4 97.4
well103 16.6 0 0.441 17 97.4 97.4
well104 16.6 0 0.441 17 97.4 97.4
well105 16.6 0 0.441 17 97.4 97.4
zone3 82.8 0 2.2 85 97.4 97.4

The zone3 criticality ranking. The losses are relative to the zone3 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 1.3E-8 85 1.1E-6 85 0.0
other 2.38E-6 68 1.62E-4 85 0.0
other 1.74E-4 51 0.00886 85 0.0
+ ( well101 well102) 6.35E-4 34 0.0216 85 0.0
+ ( well101 well103) 6.35E-4 34 0.0216 85 0.0
+ ( well101 well104) 6.35E-4 34 0.0216 85 0.0
+ ( well101 well105) 6.35E-4 34 0.0216 85 0.0
+ ( well102 well103) 6.35E-4 34 0.0216 85 0.0
+ ( well102 well104) 6.35E-4 34 0.0216 85 0.0
+ ( well102 well105) 6.35E-4 34 0.0216 85 0.0
+ ( well103 well104) 6.35E-4 34 0.0216 85 0.0
+ ( well103 well105) 6.35E-4 34 0.0216 85 0.0
+ ( well104 well105) 6.35E-4 34 0.0216 85 0.0
well101 0.0233 17 0.396 85 0.5
well102 0.0233 17 0.396 85 0.5
well103 0.0233 17 0.396 85 0.5
well104 0.0233 17 0.396 85 0.5
well105 0.0233 17 0.396 85 0.5
zone3 2.2 85 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well101 loss analysis. The losses are relative to the well101 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well101 16.6 0 0.441 17 97.4 97.4

The well101 criticality ranking. The losses are relative to the well101 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well101 0.0259 17 0.441 17 2.6
well101 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well102 loss analysis. The losses are relative to the well102 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well102 16.6 0 0.441 17 97.4 97.4

The well102 criticality ranking. The losses are relative to the well102 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well102 0.0259 17 0.441 17 2.6
well102 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well103 loss analysis. The losses are relative to the well103 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well103 16.6 0 0.441 17 97.4 97.4

The well103 criticality ranking. The losses are relative to the well103 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well103 0.0259 17 0.441 17 2.6
well103 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well104 loss analysis. The losses are relative to the well104 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well104 16.6 0 0.441 17 97.4 97.4

The well104 criticality ranking. The losses are relative to the well104 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well104 0.0259 17 0.441 17 2.6
well104 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:17 (model units)
available capacity:17 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The well105 loss analysis. The losses are relative to the well105 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
well105 16.6 0 0.441 17 97.4 97.4

The well105 criticality ranking. The losses are relative to the well105 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
well105 0.0259 17 0.441 17 2.6
well105 0.441 17 2.6

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:510 (model units)
available capacity:510 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The separation loss analysis. The losses are relative to the separation maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
train1 170 0 0.136 170 99.9 99.9
train2 170 0 0.136 170 99.9 99.9
train3 170 0 0.136 170 99.9 99.9
separation 510 0 0.409 510 99.9 99.9

The separation criticality ranking. The losses are relative to the separation maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 5.4E-10 510 2.76E-7 510 0.0
other 1.97E-6 340 6.71E-4 510 0.0
other 0.0024 170 0.408 510 0.1
separation 0.409 510 0.1

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The train1 loss analysis. The losses are relative to the train1 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V9001 170 0 0.0455 170 100.0 100.0
V9002 170 0 0.0455 170 100.0 100.0
V9003 170 0 0.0455 170 100.0 100.0
train1 170 0 0.136 170 99.9 99.9

The train1 criticality ranking. The losses are relative to the train1 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 8.02E-4 170 0.136 170 0.1
train1 0.136 170 0.1

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V9001 loss analysis. The losses are relative to the V9001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V9001 170 0 0.0455 170 100.0 100.0

The V9001 criticality ranking. The losses are relative to the V9001 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V9001 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V9002 loss analysis. The losses are relative to the V9002 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V9002 170 0 0.0455 170 100.0 100.0

The V9002 criticality ranking. The losses are relative to the V9002 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V9002 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V9003 loss analysis. The losses are relative to the V9003 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V9003 170 0 0.0455 170 100.0 100.0

The V9003 criticality ranking. The losses are relative to the V9003 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V9003 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The train2 loss analysis. The losses are relative to the train2 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V10001 170 0 0.0455 170 100.0 100.0
V10002 170 0 0.0455 170 100.0 100.0
V10003 170 0 0.0455 170 100.0 100.0
train2 170 0 0.136 170 99.9 99.9

The train2 criticality ranking. The losses are relative to the train2 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 8.02E-4 170 0.136 170 0.1
train2 0.136 170 0.1

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V10001 loss analysis. The losses are relative to the V10001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V10001 170 0 0.0455 170 100.0 100.0

The V10001 criticality ranking. The losses are relative to the V10001 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V10001 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V10002 loss analysis. The losses are relative to the V10002 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V10002 170 0 0.0455 170 100.0 100.0

The V10002 criticality ranking. The losses are relative to the V10002 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V10002 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V10003 loss analysis. The losses are relative to the V10003 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V10003 170 0 0.0455 170 100.0 100.0

The V10003 criticality ranking. The losses are relative to the V10003 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V10003 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The train3 loss analysis. The losses are relative to the train3 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V11001 170 0 0.0455 170 100.0 100.0
V11002 170 0 0.0455 170 100.0 100.0
V11003 170 0 0.0455 170 100.0 100.0
train3 170 0 0.136 170 99.9 99.9

The train3 criticality ranking. The losses are relative to the train3 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 8.02E-4 170 0.136 170 0.1
train3 0.136 170 0.1

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V11001 loss analysis. The losses are relative to the V11001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V11001 170 0 0.0455 170 100.0 100.0

The V11001 criticality ranking. The losses are relative to the V11001 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V11001 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V11002 loss analysis. The losses are relative to the V11002 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V11002 170 0 0.0455 170 100.0 100.0

The V11002 criticality ranking. The losses are relative to the V11002 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V11002 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:170 (model units)
available capacity:170 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The V11003 loss analysis. The losses are relative to the V11003 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
V11003 170 0 0.0455 170 100.0 100.0

The V11003 criticality ranking. The losses are relative to the V11003 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 170 0.0455 170 0.0
V11003 0.0455 170 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:1700 (model units)
available capacity:1700 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The midstream loss analysis. The losses are relative to the midstream maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(k model units) (k model units) (k model units) (k model units) (%) (%)
associatedGas 1.5 0.03 0.0255 1.56 96.4 98.3
oil 1.55 0 0.00311 1.56 99.8 99.8
water 1.56 0 0.00267 1.56 99.8 99.8
midstream 1.5 0.03 0.0308 1.56 96.1 98.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:1700 (model units)
available capacity:1700 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The associatedGas loss analysis. The losses are relative to the associatedGas maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(k model units) (k model units) (k model units) (k model units) (%) (%)
train1 0.501 0.01 0.00851 0.519 96.4 98.3
train2 0.501 0.01 0.00851 0.519 96.4 98.3
train3 0.501 0.01 0.00851 0.519 96.4 98.3
associatedGas 1.5 0.03 0.0255 1.56 96.4 98.3

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:567 (model units)
available capacity:567 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The train1 loss analysis. The losses are relative to the train1 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
D10001 519 0 0.139 519 100.0 100.0
G10001 504 10 5.37 519 97.0 98.9
K10001 518 0 0.922 519 99.8 99.8
H10001 519 0 0.0346 519 100.0 100.0
D10002 519 0 0.139 519 100.0 100.0
K10002 518 0 0.922 519 99.8 99.8
H10002 519 0 0.0346 519 100.0 100.0
D10003 519 0 0.139 519 100.0 100.0
K10003 518 0 0.922 519 99.8 99.8
train1 501 10 8.51 519 96.4 98.3

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:567 (model units)
available capacity:567 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The D10001 loss analysis. The losses are relative to the D10001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
D10001 567 0 0.152 567 100.0 100.0

The D10001 criticality ranking. The losses are relative to the D10001 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 566.667 0.152 567 0.0
D10001 0.152 567 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:567 (model units)
available capacity:567 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The G10001 loss analysis. The losses are relative to the G10001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
G10001 504 10 5.37 519 97.0 98.9

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:567 (model units)
available capacity:567 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The K10001 loss analysis. The losses are relative to the K10001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
K10001 566 0 1.01 567 99.8 99.8

The K10001 criticality ranking. The losses are relative to the K10001 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
K10001 0.00178 566.667 1.01 567 0.2
K10001 1.01 567 0.2

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:567 (model units)
available capacity:567 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The H10001 loss analysis. The losses are relative to the H10001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
H10001 567 0 0.0379 567 100.0 100.0

The H10001 criticality ranking. The losses are relative to the H10001 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 6.69E-5 566.667 0.0379 567 0.0
H10001 0.0379 567 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:567 (model units)
available capacity:567 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The D10002 loss analysis. The losses are relative to the D10002 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
D10002 567 0 0.152 567 100.0 100.0

The D10002 criticality ranking. The losses are relative to the D10002 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 566.667 0.152 567 0.0
D10002 0.152 567 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:567 (model units)
available capacity:567 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The K10002 loss analysis. The losses are relative to the K10002 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
K10002 566 0 1.01 567 99.8 99.8

The K10002 criticality ranking. The losses are relative to the K10002 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
K10002 0.00178 566.667 1.01 567 0.2
K10002 1.01 567 0.2

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:567 (model units)
available capacity:567 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The H10002 loss analysis. The losses are relative to the H10002 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
H10002 567 0 0.0379 567 100.0 100.0

The H10002 criticality ranking. The losses are relative to the H10002 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 6.69E-5 566.667 0.0379 567 0.0
H10002 0.0379 567 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:567 (model units)
available capacity:567 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The D10003 loss analysis. The losses are relative to the D10003 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
D10003 567 0 0.152 567 100.0 100.0

The D10003 criticality ranking. The losses are relative to the D10003 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
other 2.67E-4 566.667 0.152 567 0.0
D10003 0.152 567 0.0

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:567 (model units)
available capacity:567 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The K10003 loss analysis. The losses are relative to the K10003 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
K10003 566 0 1.01 567 99.8 99.8

The K10003 criticality ranking. The losses are relative to the K10003 maximum capacity.

downtime scenario downtime fraction impact availability loss maximum capacity availability loss
(model units) (model units) (model units) (%)
K10003 0.00178 566.667 1.01 567 0.2
K10003 1.01 567 0.2

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:567 (model units)
available capacity:567 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The train2 loss analysis. The losses are relative to the train2 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
D11001 519 0 0.139 519 100.0 100.0
G11001 504 10 5.37 519 97.0 98.9
K11001 518 0 0.922 519 99.8 99.8
H11001 519 0 0.0346 519 100.0 100.0
D11002 519 0 0.139 519 100.0 100.0
K11002 518 0 0.922 519 99.8 99.8
H11002 519 0 0.0346 519 100.0 100.0
D11003 519 0 0.139 519 100.0 100.0
K11003 518 0 0.922 519 99.8 99.8
train2 501 10 8.51 519 96.4 98.3

Snapshot status

time:21 Dec 2017 19:45
maximum capacity:567 (model units)
available capacity:567 (model units)

Downtime events snapshot

  • At the time of the run, there were no downtime events.

The D11001 loss analysis. The losses are relative to the D11001 maximum capacity.

facility expected capacity planned loss unplanned loss maximum capacity availability reliability
(model units) (model units) (model units) (model units) (%) (%)
D11001 567 0 0.152 567 100.0 100.0

The D11001 criticality ranking. The losses are relative to the D11001 maximum capacity.

downtime scenario downtime fraction impact availability loss